Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

High thermogravimetric analysis

Mixtures can be identified with the help of computer software that subtracts the spectra of pure compounds from that of the sample. For complex mixtures, fractionation may be needed as part of the analysis. Commercial instmments are available that combine ftir, as a detector, with a separation technique such as gas chromatography (gc), high performance Hquid chromatography (hplc), or supercritical fluid chromatography (96,97). Instmments such as gc/ftir are often termed hyphenated instmments (98). Pyrolyzer (99) and thermogravimetric analysis (tga) instmmentation can also be combined with ftir for monitoring pyrolysis and oxidation processes (100) (see Analytical methods, hyphenated instruments). [Pg.315]

David, The Application of Differential Thermal And Thermogravimetric Analysis to Military High Explosives , NAVORD 5802, AD 232625 (i960) 108) P. Aubertein H. Pascal, Chemical Determination of Some Explosives and Explosive Mixtures , MP 40,113-25 (1958) CA 54, 25825 (1960) 109) E.M. Bens et al, Rapid... [Pg.597]

In most of the studies discussed above, except for the meta-linked diamines, when the aromatic content (dianhydride and diamine chain extender), of the copolymers were increased above a certain level, the materials became insoluble and infusible 153, i79, lsi) solution to this problem with minimum sacrifice in the thermal properties of the products has been the synthesis of siloxane-amide-imides183). In this approach pyromellitic acid chloride has been utilized instead of PMDA or BTDA and the copolymers were synthesized in two steps. The first step, which involved the formation of (siloxane-amide-amic acid) intermediate was conducted at low temperatures (0-25 °C) in THF/DMAC solution. After purification of this intermediate thin films were cast on stainless steel or glass plates and imidization was obtained in high temperature ovens between 100 and 300 °C following a similar procedure that was discussed for siloxane-imide copolymers. Copolymers obtained showed good solubility in various polar solvents. DSC studies indicated the formation of two-phase morphologies. Thermogravimetric analysis showed that the thermal stability of these siloxane-amide-imide systems were comparable to those of siloxane-imide copolymers 183>. [Pg.35]

Ando and co-workers have reported the synthesis of a silyl-carborane hybrid diethynylbenzene-silylene polymer (108) (Fig. 66) possessing high thermal stability.136 The polymer contained Si and —C=C— group in the main chain and m-carborane and vinyl groups in the side chain. The 5% weight-loss temperature of the cured polymer in air was over 1000°C as determined by thermogravimetric analysis. [Pg.67]

In a study on the thermal and UV ageing of two commercial polyfoxymethy-lene) (POM) samples, one of which was a copolymer (see related study discussed later under Section 4.3, thermogravimetric analysis (TGA)), used in car interior applications, involving both DSC and TGA, isothermal OIT measurements were made at several different temperatures [8]. One conclusion from this study was that "extrapolation of the OIT data from high temperatures (molten state) to ambient temperatures in the solid state does not reflect effective antioxidant performance at room temperature", and thus measurements close to the melting point are not appropriate for reliable lifetime estimations. [Pg.391]

High performance liquid chromatography (HPLC) and with mass spectrometry (LC-MS) Plasma emission spectroscopy (PES) Scanning electron microscopy (SEM) with elemental X-ray analysis Thermogravimetric analysis (TGA)... [Pg.564]

All the polyimides are thermostable. They do not melt before decomposition at high temperature. In thermogravimetric analysis, the decomposition starts at more than 400°C. [Pg.585]

Figure 15. A typical thermogravimetric analysis (TGA) trace of a polymer resist that has been spin-coated and NOT prebaked. The small weight loss at low temperature is due to solvent evaporation and the high temperature weight loss is due to thermal decomposition. Figure 15. A typical thermogravimetric analysis (TGA) trace of a polymer resist that has been spin-coated and NOT prebaked. The small weight loss at low temperature is due to solvent evaporation and the high temperature weight loss is due to thermal decomposition.

See other pages where High thermogravimetric analysis is mentioned: [Pg.151]    [Pg.92]    [Pg.151]    [Pg.92]    [Pg.201]    [Pg.7]    [Pg.60]    [Pg.222]    [Pg.521]    [Pg.594]    [Pg.131]    [Pg.216]    [Pg.224]    [Pg.120]    [Pg.141]    [Pg.106]    [Pg.943]    [Pg.444]    [Pg.35]    [Pg.894]    [Pg.781]    [Pg.213]    [Pg.91]    [Pg.379]    [Pg.411]    [Pg.300]    [Pg.114]    [Pg.152]    [Pg.373]    [Pg.152]    [Pg.237]    [Pg.245]    [Pg.106]    [Pg.405]    [Pg.136]    [Pg.322]    [Pg.174]    [Pg.68]    [Pg.100]    [Pg.256]    [Pg.233]    [Pg.89]    [Pg.135]    [Pg.303]   