Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Heat transfer Lockhart-Martinelli parameters

TJse of the Lockhart-Martinelli Parameters for Heat Transfer... [Pg.259]

For sufficiently large heat flux to mass flow ratios, the nucleation mechanism predominates and the heat transfer becomes independent of the two-phase flow characteristics of the system. Thus at large values of the boiling number, the heat transfer coefficients are virtually independent of the Lockhart-Martinelli parameter, Xn. [Pg.263]

Dengler and Addoms 8 measured heat transfer to water boiling in a 6 m tube and found that the heat flux increased steadily up the tube as the percentage of vapour increased, as shown in Figure 14.4. Where convection was predominant, the data were correlated using the ratio of the observed two-phase heat transfer coefficient (htp) to that which would be obtained had the same total mass flow been all liquid (hi) as the ordinate. As discussed in Volume 6, Chapter 12, this ratio was plotted against the reciprocal of Xtt, the parameter for two-phase turbulent flow developed by Lockhart and Martinelli(9). The liquid coefficient hL is given by ... [Pg.775]


See other pages where Heat transfer Lockhart-Martinelli parameters is mentioned: [Pg.43]    [Pg.259]    [Pg.492]    [Pg.43]    [Pg.350]    [Pg.27]   
See also in sourсe #XX -- [ Pg.260 ]