Flowmeters, differential pressure venturi meters

The flow of fluids is most commonly measured using head flowmeters. The operation of these flowmeters is based on the Bernoulli equation. A constriction in the flow path is used to increase the flow velocity. This is accompanied by a decrease in pressure head and since the resultant pressure drop is a function of the flow rate of fluid, the latter can be evaluated. The flowmeters for closed conduits can be used for both gases and liquids. The flowmeters for open conduits can only be used for liquids. Head flowmeters include orifice and venturi meters, flow nozzles, Pitot tubes and weirs. They consist of a primary element which causes the pressure or head loss and a secondary element which measures it. The primary element does not contain any moving parts. The most common secondary elements for closed conduit flowmeters are U-tube manometers and differential pressure transducers. [Pg.268]

Head-type flowmeters include orifice plates, venturi tubes, weirs, flumes, and many others. They change the velocity or direction of the flow, creating a measurable differential pressure, or "pressure head," in the fluid. Head metering is one of the most ancient of flow detection techniques. There is evidence that the Egyptians used weirs for measurement of irrigation water flows in the days of the Pharaohs and that the Romans used orifices to meter water to households in Caesar s time. In the 18th century, Bernoulli established the basic relationship between the pressure head and velocity head, and Venturi published on the flow tube bearing his name. [Pg.399]

Meters that measure differential pressures over the flowmeter and such pressure changes that can be interpreted as flowrates. Such flowmeters with a large number of designs include orifices, venturi tubes, pitot tubes, elbow taps, etc. Fluids that result in changes of the cross-sectional area due to erosion, corrosion, or deposition of solids obviously change the calibrations. These meters tend to be relatively cheap but are often not very accurate. [Pg.1535]


See other pages where Flowmeters, differential pressure venturi meters is mentioned: [Pg.153]   
See also in sourсe #XX -- [ Pg.10 , Pg.11 , Pg.12 , Pg.13 , Pg.14 , Pg.15 , Pg.16 , Pg.17 ]




SEARCH



Flowmeter differentials

Flowmeters

Pressure Flowmeters

Pressure meters

Venturi meter

© 2024 chempedia.info