The flow of fluids is most commonly measured using head flowmeters. The operation of these flowmeters is based on the Bernoulli equation. A constriction in the flow path is used to increase the flow velocity. This is accompanied by a decrease in pressure head and since the resultant pressure drop is a function of the flow rate of fluid, the latter can be evaluated. The flowmeters for closed conduits can be used for both gases and liquids. The flowmeters for open conduits can only be used for liquids. Head flowmeters include orifice and venturi meters, flow nozzles, Pitot tubes and weirs. They consist of a primary element which causes the pressure or head loss and a secondary element which measures it. The primary element does not contain any moving parts. The most common secondary elements for closed conduit flowmeters are U-tube manometers and differential pressure transducers. [Pg.268]

In laminar flow elements, the pressure drop and flow are in a linear relationship. The laminar flow element can be used in combination with either a differential-pressure- or a thermal-type flow detector. These flowmeters provide better rangeability at about the same cost as sonic nozzles. [Pg.402]

In this approach a gas flowmeter is used to determine the amount adsorbed. It can be of a differential type, as in Figure 3.7 (e.g. with a differential catharometer or a differential pressure drop flowmeter) or a simple form with either a sonic nozzle (Figure 3.8) or a thermal detector (Figure 3.9). The last provides a signal which depends on the heat capacity, thermal conductivity and mass flow of the gas it is usually referred to as a mass flowmeter although there is no direct measurement of mass. [Pg.57]

Differential pressure flowmeters are suited to high- and moderate-velocity flow of gas and clean, low-viscosity liquids. Venturi flowmeters (Fig. 18.9(a)) are the most accurate, but they are large and expensive. Orifice flowmeters (Fig. 18.9(b)) aresmaUer, less expensive, and much less accurate than venturi flowmeters. Nozzle flowmeters (Fig. 18.9(c)) are a compromise between venturi and orifice flowmeters. Pipe-bend flowmeters (Fig. 18.9(d)), which can essentially be installed in any bend in an existing piping system, are used primarily for gross flow rate measurements. Pitot-static flowmeters (Fig. 18.9(e)) are used in flows which have a large cross-sectional area, such as in wind tunnels. Pitot-static flowmeters are also used in freestream applications such as airspeed indicators for aircraft. [Pg.1927]


See other pages where Flowmeters, differential pressure flow nozzles is mentioned: [Pg.422]   
See also in sourсe #XX -- [ Pg.10 , Pg.11 , Pg.12 , Pg.13 , Pg.14 , Pg.15 , Pg.16 , Pg.17 , Pg.18 ]




SEARCH



Flowmeter differentials

Flowmeters

Nozzle

Nozzle, flow

Nozzle, nozzles

Pressure Flowmeters

© 2024 chempedia.info