The filament-wound pipe weep point is less than 0.009 in./in. The design is at a strain of 0.0018 in./in. providing a 5 to 1 safety factor. For transient design conditions a strain of 0.0030 in./in. is used providing a 3 to 1 safety factor. [Pg.782]

The weep point or strain-to-first-crack in a wall for filament-wound pipe constructed using isophthalic plastic is currently found to be not less than 0.009 in./in. This has been repeatedly demonstrated by careful coupon testing and burst testing of pipes with strain gauge instrumentation attached. [Pg.214]