Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Electrochemical impedance spectroscopy Bode plot

Electrochemical impedance spectroscopy (EIS) profiles, measured as a function of the interrogating frequency, can be represented on both Bode and Nyquist plots. The two-component Bode plot presents a comprehensive and... [Pg.166]

Fig. 1 Representative a Nyquist and b Bode plots from electrochemical impedance spectroscopy measurements (HubrechtJ (1998) Metals as Biomaterials, Helsen J, Breme H (eds) John WUey Sons Limited. Reproduced with permission)... Fig. 1 Representative a Nyquist and b Bode plots from electrochemical impedance spectroscopy measurements (HubrechtJ (1998) Metals as Biomaterials, Helsen J, Breme H (eds) John WUey Sons Limited. Reproduced with permission)...
The immittance analysis can be performed using different kinds of plots, including complex plane plots of X vs. R for impedance and B vs. G for admittance. These plots can also be denoted as Z" vs. Z and Y" vs. Y, or Im(Z) vs. Rc(Z), and Im( Y) vs. Re( Y). Another type of general analysis of immittance is based on network analysis utilizing logarithmic Bode plots of impedance or admittance modulus vs. frequency (e.g., log Y vs. logo)) and phase shift vs. frequency ( vs. log co). Other dependencies taking into account specific equivalent circuit behavior, for instance, due to diffusion of reactants in solution, film formation, or electrode porosity are considered in - electrochemical impedance spectroscopy. Refs. [i] Macdonald JR (1987) Impedance spectroscopy. Wiley, New York [ii] Jurczakowski R, Hitz C, Lasia A (2004) J Electroanal Chem 572 355... [Pg.350]

Electrochemical Impedence Spectroscopy (EIS) data are shown in Figure 33.15 (Bode plot) and Figure 33.16 (phase angle-frequency plot). All the samples exhibit... [Pg.736]

Figure 14.12. Electrochemical impedance spectroscopy based in situ DNA sensing (A Nyquist plots and (B corresponding Bode plots of as grown, DNA probe against anthrax lethal factor (pLF -modified, and dsDNA-modified GaNNWs at different concentrations of LF targets (arrows indicate increasing concentration, in situ DNA hybridization detection. ... Figure 14.12. Electrochemical impedance spectroscopy based in situ DNA sensing (A Nyquist plots and (B corresponding Bode plots of as grown, DNA probe against anthrax lethal factor (pLF -modified, and dsDNA-modified GaNNWs at different concentrations of LF targets (arrows indicate increasing concentration, in situ DNA hybridization detection. ...
When a range of frequencies is applied to the DUT, both El and ECI techniques are called spectroscopies, i.e., electrical impedance spectroscopy and electrochemical impedance spectroscopy. Electrochemical impedance spectroscopy (EIS) profiles, measured as a function of the interrogating frequency, can be presented by two popular plots complex plane impedance diagrams, sometimes called Nyquist or Cole-Cole plots, and Bode (I Z I and 6) plots (Fig. 2). As the impedance, Z, is composed of a real and an imaginary part, the Nyquist plot shows the relationship of the imaginary component of impedance, Z" (on the Y-axis), to the real component of the impedance, Z (on the X-axis), at each frequency. A diagonal line with a slope of 45° on a Nyquist plot represents the Warburg... [Pg.1366]

Fig. 2 Representative (a) complex plane diagrams (Nyquist or Cole-Cole plots) and (b) Bode plots from electrochemical impedance spectroscopy measurements... Fig. 2 Representative (a) complex plane diagrams (Nyquist or Cole-Cole plots) and (b) Bode plots from electrochemical impedance spectroscopy measurements...
Electrochemical impedance spectroscopy is useful in the evaluation of coatings, the elucidation of transport phenomena in electrochemical systems, and the determination of corrosion mechanisms and rates. Bode and Nyquist plots are the most common data output formats, and an example of each for a simple parallel-connected resistance-capacitance circuit are shown in Figs. 31.3, and 31.4, respectively. The Bode plot format shows the... [Pg.888]

Fig. 10 Cole-Cole plot (a) and Bode plot (b) of electrochemical impedance spectroscopy (EIS) analyses of the MEA represented in Fig. 9 after low current density operation before dry treatment. Anode/cathode, pure H, or H -CO (10ppm)/Oj. Current density, 200mA... Fig. 10 Cole-Cole plot (a) and Bode plot (b) of electrochemical impedance spectroscopy (EIS) analyses of the MEA represented in Fig. 9 after low current density operation before dry treatment. Anode/cathode, pure H, or H -CO (10ppm)/Oj. Current density, 200mA...
Figure 11. (a) A commonly used circuit model representing resistive and capacitive elements in a corrosion cell, and (b) graphical derivation of values for / s and from a Bode plot of the modulus and phase angle values as a function of applied sweep frequency in an electrochemical impedance spectroscopy experiment. [Pg.673]


See other pages where Electrochemical impedance spectroscopy Bode plot is mentioned: [Pg.556]    [Pg.309]    [Pg.188]    [Pg.536]    [Pg.215]    [Pg.48]    [Pg.286]    [Pg.6314]    [Pg.514]    [Pg.408]    [Pg.479]    [Pg.241]    [Pg.267]    [Pg.188]   
See also in sourсe #XX -- [ Pg.384 , Pg.384 ]