Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Duct design

Detailed Includes the follow ing subtasks detailed design of ventilation Duct design... [Pg.18]

It is normal in duct design to use volume flow rate rather than the mass flow rate, giving... [Pg.710]

Duct design The process of sizing ductwork to ensure the optimum performance in initial costs, running costs, and the distribution of air in a duct distribution system. The design techniques may be... [Pg.1431]

Rain louver or weather louver A fresh air inlet to a duct designed to reduce the ingress of driving rain. [Pg.1471]

Grille noise will only be serious if long throws are used, or if poor duct design requires severe throttling on outlet dampers. [Pg.315]

The rough duct design method may result in premature dust deposition or excessive system erosion (due to incorrect duct sizes and velocities)... [Pg.755]

Hence, even if the rough duct design technique is selected, some form of balancing still should be performed so that the final duct sizes are close to optimal (in terms of pressure and velocity). [Pg.755]

Ducts are used to transport the exhaust air and its contaminants to the collection area. An important feature of duct design is reduction of resistance to air flow from friction within the wall, aggravated by unnecessary curves and bends (particularly right-angled bends), as well as junctions with other ducts at sharp angles, collections of dust, and changes in duct diameter. [Pg.135]

Figure 13 Duct designs of air concentrators with vertical airflow (a) straight, (b) zigzag and (c) stacked reverse triangles. (Reproduced with permission from Ref. 4.)... Figure 13 Duct designs of air concentrators with vertical airflow (a) straight, (b) zigzag and (c) stacked reverse triangles. (Reproduced with permission from Ref. 4.)...
OTEC plant system characteristics OTEC plant system overall layout Land-hased containment system (LCBS) design Power system design Water ducting design Asset acquisition Project achedule OTEC plant system deployment LBCS deployment Inspection, maintenance and repair Safety analysis... [Pg.164]

Duct design for residential ACCA winter and summer air. condidonit ... [Pg.66]

The test sections of the three hot gas ducting designs were instrumented in order to get the necessary information. [Pg.229]

The reactor has natural coolant circulation in the primary circuit under all modes of operation. Before returning to the reactor, the secondary coolant passes through a system of parallel finned tubes which form the heat exchanger to atmosphere of the PDHRS. To ensure adequate heat transfer from these tubes, they are contained in a vertical duct designed to enhance the air flow. However such heat transfer is undesirable in normal operation so the entry to and exit from the tube region of the duct are closed by a system of louvres. When the temperature in the chamber between the louvres rises to 80 - 90C, direct actioning devices (thermostatic or based on a shape-memory material ) will actuate to open the louvres and initiate the PDHRS action to cool the reactor. [Pg.490]

Where corrosive chemicals are used, the fume exhaust or ordinary ferris construction would not stand up to the atmosphere. The duct should be of a special metallic duct designed for the specific atmosphere. Many corrosive atmospheres can be handled by stainless steel or other metal ducts. [Pg.393]

High-velocity duct design Professional praposak ft reports... [Pg.71]

Fig. 1.1.3. Flour mill cyclones manufactured by the Wolf Company (The Wolf Company (1922) Flour Mill Machinery catalog, Chambersburg, Pennsylvania) during the early 1920s. Note the variety of inlet duct designs used to feed multiple cyclones. Courtesy of Theodore R. Heizen and Pond Lily Mill Restorations (http //home.earthlink.net/ alstallsinith/index.htm)... Fig. 1.1.3. Flour mill cyclones manufactured by the Wolf Company (The Wolf Company (1922) Flour Mill Machinery catalog, Chambersburg, Pennsylvania) during the early 1920s. Note the variety of inlet duct designs used to feed multiple cyclones. Courtesy of Theodore R. Heizen and Pond Lily Mill Restorations (http //home.earthlink.net/ alstallsinith/index.htm)...

See other pages where Duct design is mentioned: [Pg.484]    [Pg.39]    [Pg.210]    [Pg.430]    [Pg.434]    [Pg.445]    [Pg.445]    [Pg.754]    [Pg.769]    [Pg.484]    [Pg.329]    [Pg.315]    [Pg.33]    [Pg.902]    [Pg.262]    [Pg.161]    [Pg.82]   
See also in sourсe #XX -- [ Pg.755 ]




SEARCH



Design Parameters of Ducted Rockets

Ducting

Ducts

© 2024 chempedia.info