Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Difference point general column sections

This develops the general algorithm of calculation of minimum reflux mode for the columns with two feed inputs at distillation of nonideal zeotropic and azeotropic mixtures with any number of components. The same way as for the columns with one feed, the coordinates of stationary points of three-section trajectory bundles are defined at the beginning at different values of the parameter (L/V)r. Besides that, for the intermediate section proper values of the system of distillation differential equations are determined for both stationary points from the values of phase equihbrium coefficients. From these proper values, one finds which of the stationary points is the saddle one Sm, and states the direction of proper vectors for the saddle point. The directions of the proper vectors obtain linear equations describing linearized boundary elements of the working trajectory bundle of the intermediate section. We note that, for sharp separation in the top and bottom sections, there is no necessity to determine the proper vectors of stationary points in order to obtain linear equations describing boundary elements of their trajectory bundles, because to obtain these linear equations it is sufficient to have... [Pg.179]

A different issue is one that is quite common in the Pharmaceutical industry. A relatively frequent situation that arises is the need to identify a 0.1% impurity from a reaction mixture or metabolism sample. These samples are often quite convoluted in terms of the amount of compounds present as well as the general complexity of the separation, akin to a natural products extract, as can be seen in Fig. 19.19. However, to simplify this scenario to just a two-component mixture is appropriate for this section. Under common LC-NMR systems, it is typically required to have at least 50 pg of material for a complete structure elucidation (to enable the collection of long-range heteronu-clear correlation data, HMBC). Therefore, one must be able to load 50 mg of the mixture on the column. Keep in mind, that if a ID 1H spectrum is all that is needed (in the case of a regiochemical issue in an aromatic system) this task becomes more amenable. The point trying to be made is that LC-NMR is a fantastic technique, but it must be used in... [Pg.738]

The section that follows adapts and extends the CPM concepts to the specific case of an MCS. It is crucial to note that the specific case of the MCS differs from the general case for distillation presented elsewhere in this book in that the flowrates are not constant in an MCS. This means that the reflux ratio (ta) is not constant down the length of the column. All CPMs drawn up to this point have made use of the constant flow assumption, and the following section will discuss the changes that arise in the absence of this assumption. [Pg.299]


See other pages where Difference point general column sections is mentioned: [Pg.200]    [Pg.1273]    [Pg.338]    [Pg.91]    [Pg.458]    [Pg.153]    [Pg.182]    [Pg.34]    [Pg.401]    [Pg.645]    [Pg.668]    [Pg.4]    [Pg.542]    [Pg.125]    [Pg.147]    [Pg.296]    [Pg.136]    [Pg.233]    [Pg.230]    [Pg.89]    [Pg.62]    [Pg.136]    [Pg.670]    [Pg.749]    [Pg.191]    [Pg.873]    [Pg.330]    [Pg.218]    [Pg.201]    [Pg.115]    [Pg.145]    [Pg.276]    [Pg.7]    [Pg.400]   
See also in sourсe #XX -- [ Pg.63 , Pg.65 , Pg.66 , Pg.119 , Pg.125 ]




SEARCH



Difference point

General Section

General points

© 2024 chempedia.info