Detectors viscometer, dead

Table I indicates good agreement between the molecular weight distribution statistics obtained by coupled GPC/Viscometer method and the nominal values for t BS 706. The discrepancy between the Mark-Houwink parameters obtained here and the reported values for polystyrene standard ( ) in THF at 25°C (i.e., a = 0,706 and k = 1.60 x 10 ) may in part be due to the uncertainty involved in the determination of the dead volume between DRI and viscometer detectors. Our simulation studies over a range of dead volume values (0 to 120u)l) showed that a and k are quite sensitive to the dead volume between the detectors. Larger dead volume results in smaller o and larger k values. This is a direct result of a clockwise rotation of log [q] vs. log M(v) curve (Figure 12) which occurs when the dead volume correction is applied in quantitative analysis. The effect on the molecular weight statistics, however, appeared to... Table I indicates good agreement between the molecular weight distribution statistics obtained by coupled GPC/Viscometer method and the nominal values for t BS 706. The discrepancy between the Mark-Houwink parameters obtained here and the reported values for polystyrene standard ( ) in THF at 25°C (i.e., a = 0,706 and k = 1.60 x 10 ) may in part be due to the uncertainty involved in the determination of the dead volume between DRI and viscometer detectors. Our simulation studies over a range of dead volume values (0 to 120u)l) showed that a and k are quite sensitive to the dead volume between the detectors. Larger dead volume results in smaller o and larger k values. This is a direct result of a clockwise rotation of log [q] vs. log M(v) curve (Figure 12) which occurs when the dead volume correction is applied in quantitative analysis. The effect on the molecular weight statistics, however, appeared to...
Determination of the Dead Volume Between the Viscometer and the Concentration Detector... [Pg.289]

Another requirement for accurate GPC/Viscometer data analysis is accounting for the dead volume (aV) between the viscometer and the concentration detector. [Pg.289]

Figure 9. Slope versus AV plot for the determination of the dead volume between DRI and viscometer detectors. Figure 9. Slope versus AV plot for the determination of the dead volume between DRI and viscometer detectors.

See other pages where Detectors viscometer, dead is mentioned: [Pg.18]    [Pg.130]    [Pg.198]   


SEARCH



DEAD

DeADeS

Detectors viscometer

Viscometer

© 2024 chempedia.info