Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Density data collection

Density Data Collected by Three Different Students ... [Pg.37]

The advent of CCD detectors for X-ray diffraction experiments has raised the possibility of obtaining charge density data sets in a much reduced time compared to that required with traditional point detectors. This opens the door to many more studies and, in particular, comparative studies. In addition, the length of data collection no longer scales with the size of the problem, thus the size of tractable studies has certainly increased but the limit remains unknown. Before embracing this new technology, it is necessary to evaluate the quality of the data obtained and the possible new sources of error. The details of the work summarized below has either been published or submitted for publication elsewhere [1-3]. [Pg.224]

This chapter on micromeritics will deal specifically with surface area, porosimetry, and density measurements. It is designed to introduce the importance of the specific technique in pharmaceutics and briefly describe the theory, instrumentation, and data collection involved. Examples are presented to... [Pg.254]

Figure 3 shows an ordering map for this Lennard-Jones system, with the translational order t (of Eq. [2]) plotted against the bond-orientational order Qs (of Eq. [5]). It can be observed that the data, collected over a wide range of temperatures and densities, collapse onto two distinct equilibrium branches... [Pg.132]

Figure 6.6 0.30 nm resolution double difference anomalous electron density map of the catalytic site of D.gigas [NiFe] hydrogenase, with X-ray data collected at both sides of the Fe absorption edge (Volbeda et al. 1996). [Pg.117]

As is evident from Eqs. (1.36) and (1.37), and from the classical treatment as well, the effect of resonance on the intensity of X-ray scattering is pronounced when E E0, that is, in the vicinity of the absorption edges. Even for data collected at other wavelengths, it is necessary to correct the structure factors for anomalous scattering before the electron density can be calculated by the Fourier inversions of Eqs. (1.22) and (1.26), as further discussed in chapter 5. The anomalous scattering factors needed for this purpose are available in the literature (International Tables for X-ray Crystallography 1974, Kissel and Pratt 1990). [Pg.15]

Transferability of atomic densities was tested by Brock et al. (1991), who applied atomic charge density parameters from an accurate low-temperature study of perylene (I) to data collected at five and six different temperatures on naphthalene (II) and anthracene (III), respectively. The molecules are all aromatic hydrocarbons. To reduce the number of variables, all H atoms were assigned... [Pg.273]


See other pages where Density data collection is mentioned: [Pg.98]    [Pg.98]    [Pg.384]    [Pg.17]    [Pg.18]    [Pg.181]    [Pg.57]    [Pg.227]    [Pg.56]    [Pg.210]    [Pg.80]    [Pg.126]    [Pg.229]    [Pg.85]    [Pg.79]    [Pg.147]    [Pg.174]    [Pg.97]    [Pg.312]    [Pg.117]    [Pg.175]    [Pg.324]    [Pg.350]    [Pg.39]    [Pg.371]    [Pg.228]    [Pg.448]    [Pg.449]    [Pg.84]    [Pg.227]    [Pg.32]    [Pg.152]    [Pg.421]    [Pg.55]    [Pg.63]    [Pg.166]    [Pg.180]    [Pg.184]    [Pg.240]    [Pg.271]    [Pg.224]    [Pg.34]    [Pg.46]   


SEARCH



DATA DENSITY

Data collection

© 2024 chempedia.info