Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Cyclic voltammetry voltammogram

The above reactions were also followed by cyclic voltammetry. Voltammograms measured in a uranyl(VI) containing melt under an inert atmosphere exhibit two cathodic and two corresponding anodic waves (Figure 6.13.2a) due to two reversible one-electron reactions. The cathodic processes can be expressed by the following equations ... [Pg.510]

Flavin adenine dinucleotide (FAD) has been electropolymerized using cyclic voltammetry. Cyclic voltammograms of poly (FAD) modified electrode were demonstrated dramatic anodic current increasing when the electrolyte solution contained NADH compare with the absence of pyridine nucleotide. [Pg.363]

For more detailed information on the theory of cyclic voltammetry, and the interpretation of cyclic voltammograms, see references (1,7,19,20). [Pg.40]

For the in situ characterization of modified electrodes, the method of choice is electrochemical analysis by cyclic voltammetry, ac voltammetry, chronoamperometry or chronocoulometry, or rotating disk voltametry. Cyclic voltammograms are easy to interpret from a qualitative point of view (Fig, 1). The other methods are less direct but they can yield quantitative data more readily. [Pg.60]

In practice, AGq will also depend on the coverage of the adsorbate, 6. Since this effect has direct implications for cyclic voltammetry, it will be discussed in more detail in Section 3.3.1 on theoretical cyclic voltammograms. [Pg.60]

Cyclic voltammetry is perhaps the most important and widely used technique within the field of analytical electrochemistry. With a theoretical standard hydrogen electrode at hand, one of the first interesting and challenging applications may be to try to use it to make theoretical cyclic voltammograms (CVs). In following, we set out to do this by attempting to calculate the CV for hydrogen adsorption on two different facets of platinum the (111) and the (100) facets. [Pg.60]

Electrochemically active compounds can be evaluated using a potentiometer to generate a cyclic voltammogram for the analyte. Cyclic voltammetry will allow the analyst to determine whether the compound can be oxidized or reduced, to choose the appropriate potential to use in the electrochemical detector, and to establish whether oxidation or reduction is irreversible. Irreversible oxidation or reduction of the analyte could be predictive of problems with electrode poisoning and reduced sensitivity of the electrochemical detector over time. Turberg et al. used EC detection at an applied potential of -1-600 mV to analyze for ractopamine. [Pg.313]

The facilitated ion transfers of some alkaline earth metals have been also studied in the DCE systems by the cyclic voltammetry. These systems perhaps have not been studied by any solvent extraction methods yet. Typical voltammograms in the N15C5 diffusion-control systems are shown in Fig. 6. The aqueous supporting electrolyte was MgCl2 instead of MgS04 in these measurements because BaS04 precipitated. [Pg.636]

Fig. 4. Voltammograms in 0.1M Eti+NClOi+ZCH CNj rT = 1.2X1 O 8 mol/cm. Curve As Cyclic voltammetry of Pt/poly-Co -NI TPP at 20 mv/s = 200pA/cm. Curve B Four-electrode voltammetry of Pt/poly-Co( -NHi(,)TPP/Au sandwich electrode with E u = 0.0 Vj Ep scanned negatively at 5 mV/s = 400pA/cm. Curve Ci Surface profilometry of a poly-Co(o-NH2)TPP film on Sn02/glassj Tt = 7.6X10 9 mol/cm. (Reproduced from Ref. 6. Copyright 1987 American Chemical Society.)... Fig. 4. Voltammograms in 0.1M Eti+NClOi+ZCH CNj rT = 1.2X1 O 8 mol/cm. Curve As Cyclic voltammetry of Pt/poly-Co -NI TPP at 20 mv/s = 200pA/cm. Curve B Four-electrode voltammetry of Pt/poly-Co( -NHi(,)TPP/Au sandwich electrode with E u = 0.0 Vj Ep scanned negatively at 5 mV/s = 400pA/cm. Curve Ci Surface profilometry of a poly-Co(o-NH2)TPP film on Sn02/glassj Tt = 7.6X10 9 mol/cm. (Reproduced from Ref. 6. Copyright 1987 American Chemical Society.)...
Benzo[r]bcnzo[3,4]cinnolino[l,2- ]cinnoline 61 and a series of 5,6-dihydrobenzo[c]cinnoline derivatives, including compounds 62, were studied by cyclic voltammetry. The unusual shape of the voltammograms of the investigated compounds can be explained by an EiE-DISP mechanism with a slow disproportionation reaction <1996JA5020>. [Pg.378]

Wangfuengkanagul and Chailapakul [9] described the electroanalysis of ( -penicillamine at a boron-doped diamond thin film (BDD) electrode using cyclic voltammetry. The BDD electrode exhibited a well-resolved and irreversible oxidation voltammogram, and provided a linear dynamic range from 0.5 to 10 mM with a detection limit of 25 pM in voltammetric measurement. In addition, penicillamine has been studied by hydrodynamic voltammetry and flow injection analysis with amperometric detection using the BDD electrode. [Pg.134]

The first steps to the understanding of the nature of the surface oxide on platinum came with the advent of cyclic voltammetry and, as was noted above, the first major hurdle to overcome in trying to interpret the form of the Pt voltammogram was the purity of the electrochemical system. Early... [Pg.253]

Dynamic properties. On the basis of cyclic voltammetry, Diaz et al. (1981) showed that thin films of polypyrrole on an electrode immersed in acetonitrile could be repeatedly driven between the conducting and insulating states, as shown by the stability of the cyclic voltammograms of the films (see Figure 3.73). [Pg.341]

Electron transfer of the glucose oxidase/polypyrrole on the electrode surface was confirmed by differential pulse voltammetiy and cyclic voltammetry. The glucose oxidase clearly exhibited both reductive and oxidative current peaks in the absence of dissolved oxygen in these voltammograms. These results indicate that electron transfer takes place from the electrode to the oxidized form of glucose oxidase and the reduced form is oxidized by electron transfer to the electrode through polypyrrole. It may be concluded that polypyrrole works as a molecular wire between the adsorbed glucose oxidase and the platinum electrode. [Pg.342]

Cyclic Voltammetry. Figure 1 shows the cyclic voltammograms (CV s) determined for the three crystal planes in a clean (CO free)... [Pg.485]


See other pages where Cyclic voltammetry voltammogram is mentioned: [Pg.242]    [Pg.179]    [Pg.242]    [Pg.179]    [Pg.28]    [Pg.32]    [Pg.33]    [Pg.560]    [Pg.561]    [Pg.581]    [Pg.267]    [Pg.27]    [Pg.471]    [Pg.70]    [Pg.70]    [Pg.670]    [Pg.306]    [Pg.263]    [Pg.17]    [Pg.26]    [Pg.126]    [Pg.61]    [Pg.80]    [Pg.256]    [Pg.198]    [Pg.498]    [Pg.115]    [Pg.117]    [Pg.574]    [Pg.444]    [Pg.178]    [Pg.390]    [Pg.136]    [Pg.417]    [Pg.417]    [Pg.420]    [Pg.453]   


SEARCH



Cyclic voltammetry

Cyclic voltammogram

Cyclic voltammograms

Voltammogram

Voltammograms

© 2024 chempedia.info