Vapor binding, or air lock, is another common cause of household radiator malfunction. Often, the vapor accumulating in the radiator is CO,2, rather than air. The C02 originates from the thermal decomposition of carbonates in the boiler. Regardless, air and C02 form a noncondensable vapor in the radiator. These noncondensables mix with the steam in the radiator. The noncondensables then reduce the concentration of the steam, by dilution. The diluted steam has a lower partial pressure than pure steam. The lower the partial pressure of the steam, the more difficult it is to condense. As the rate of condensation of the steam drops, so does the heat radiated by the radiator. [Pg.149]