Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Coatings precision

Uses. Approximately 70% of the U.S. production is used to make poly(tetramethylene ether glycol) [25190-06-1] (PTMEG), also known as poly-THE, which is used in the production of urethane elastomers, polyurethane fibers (ether-based spandex), and copolyester—ether elastomers. PTMEG is also the fastest growing use (see PoLYETPiERS, TETRAHYDROFURAn). The remaining production is used as a solvent for the manufacture of poly(vinyl chloride) cements and coating, precision magnetic tape, a reaction solvent in the production of pharmaceuticals, and other miscellaneous uses. [Pg.429]

The particular colors that are observed at different angles will depend critically on the thickness of the thin film coating. Precision instrumentation is required to carefully control film thickness during production. The magnitude of the optical effect depends on the density of flakes in the ink, while the quality of the optical effect depends on the precise orientation or alignment of these flakes with respect to the paper surface. [Pg.156]

G. W. Coates, Precise Control of Polyolefin Stereochemistry Using Single-Site Metal Catalysts, Chem. Rev. 100, 1223-1252 (2000). [Pg.176]

Keywords Biopolymers, seed coating, precision agriculture, crop productivity... [Pg.461]

Vented pan processes offer better coating precision and drying efficiency compared to conventional pan-coating, both of which can contribute to improved economics. Better precision is generally realized due to more uniform spray configurations and more uniform drying, which allows application of uniform thin film coats. Better drying efficiency allows faster coat application, which can reduce overall process time and the added physical stress associated with that time. [Pg.173]

A major advance in force measurement was the development by Tabor, Win-terton and Israelachvili of a surface force apparatus (SFA) involving crossed cylinders coated with molecularly smooth cleaved mica sheets [11, 28]. A current version of an apparatus is shown in Fig. VI-4 from Ref. 29. The separation between surfaces is measured interferometrically to a precision of 0.1 nm the surfaces are driven together with piezoelectric transducers. The combination of a stiff double-cantilever spring with one of a number of measuring leaf springs provides force resolution down to 10 dyn (10 N). Since its development, several groups have used the SFA to measure the retarded and unretarded dispersion forces, electrostatic repulsions in a variety of electrolytes, structural and solvation forces (see below), and numerous studies of polymeric and biological systems. [Pg.236]

This polymerization is carried out in the two stages indicated above precisely because of the insolubility and infusibility of the final product. The first-stage polyamide, structure [IX], is prepared in polar solvents and at relatively low temperatures, say, 70°C or less. The intermediate is then introduced to the intended application-for example, a coating or lamination-then the second-stage cyclization is carried out at temperatures in the range 150-300°C. Note the formation of five-membered rings in the formation of the polyimide, structure [X], and also that the proportion of acid to amine groups is 2 1 for reaction (5.II). [Pg.335]

Fouling of the pH sensor may occur in solutions containing surface-active constituents that coat the electrode surface and may result in sluggish response and drift of the pH reading. Prolonged measurements in blood, sludges, and various industrial process materials and wastes can cause such drift. Therefore, it is necessary to clean the membrane mechanically or chemically at intervals that are consistent with the magnitude of the effect and the precision of the results requited. [Pg.466]


See other pages where Coatings precision is mentioned: [Pg.357]    [Pg.320]    [Pg.73]    [Pg.271]    [Pg.469]    [Pg.478]    [Pg.357]    [Pg.320]    [Pg.73]    [Pg.271]    [Pg.469]    [Pg.478]    [Pg.1973]    [Pg.117]    [Pg.12]    [Pg.374]    [Pg.377]    [Pg.72]    [Pg.151]    [Pg.532]    [Pg.40]    [Pg.129]    [Pg.172]    [Pg.377]    [Pg.462]    [Pg.394]    [Pg.451]    [Pg.5]    [Pg.42]    [Pg.48]    [Pg.51]    [Pg.44]    [Pg.51]    [Pg.102]    [Pg.195]    [Pg.513]    [Pg.78]    [Pg.161]    [Pg.207]    [Pg.244]    [Pg.396]    [Pg.304]    [Pg.305]    [Pg.307]    [Pg.307]    [Pg.307]   
See also in sourсe #XX -- [ Pg.133 ]




SEARCH



© 2024 chempedia.info