Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Tests cascade

Herrig, L.J., Emery, J.C., and Erwin, J.R., Systematic Two-Dimensional Cascade Tests of NACA 65 Series Compressor Blades at Low Speed, NACA R.M. E 55H11 (1955). [Pg.317]

Cascade test (described in Dutch standard NEN 7349) provides information on long-term leaching from a granular material. In this test the material is brought into contact with acidified demineralized water five times in succession for 23 h. The cumulative L/S (liquid/solid) ratio is 100 1 kg1. This test also yields an emission, expressed in mg kg-1. [Pg.175]

Depending on the requirements, C-scan or a cascading display are used. These types of display facilitate tests for internal damage below the surface with low-frequency eddy currents in addition to high-frequency tests for surface cracks. [Pg.307]

The original work by NACA and NASA is the basis on which most modern axial-flow compressors are designed. Under NACA, a large number of blade profiles were tested. The test data on these blade profiles is published. The cascade data conducted by NACA is the most extensive work of its kind. In most commercial axial-flow compressors NACA 65 series blades are used. These blades are usually specified by notation similar to the following 65-(18) 10. This notation means that the blade has a lift coefficient of 1.8, a profile shape 65, and a thickness/chord ratio of 10%. The lift coefficient can be directly related to the blade camber angle by the following relationship for 65 series blades ... [Pg.279]

Figure 7-11. Apparatus for testing axial-flow cascade model. Figure 7-11. Apparatus for testing axial-flow cascade model.
Figure 9-34A. Efficiency versus C-factor for various metai packings. Iso-octane/toluene, 740 mm Hg, reflux ratio 14 1,15-in. i.D. column, 10-ft bed height. Not Glitsch test data. Note CMR = Cascade Miniring . Used by permission of Glitsch, Inc., Bull. 345. Figure 9-34A. Efficiency versus C-factor for various metai packings. Iso-octane/toluene, 740 mm Hg, reflux ratio 14 1,15-in. i.D. column, 10-ft bed height. Not Glitsch test data. Note CMR = Cascade Miniring . Used by permission of Glitsch, Inc., Bull. 345.
Smaller items are tested in self-contained cabinets with a chamber the size of a large domestic refrigerator. Two-stage and three-stage systems are used, with R.13 in cascade at the lower end and R.22 for the high stage(s). [Pg.226]

There are a number of assay formats available to test drugs in a functional mode. As discussed in Chapter 2, a main theme throughout the various stimulus-response cascades found in cells is the amplification of receptor stimulus occurring as a function of the distance, in biochemical steps and reactions, away from the initial receptor event. Specifically, the further down the stimulus-... [Pg.80]

Thromboplastin A substance that triggers the coagulation cascade. Tissue factor is a naturally-occurring thromboplastin and is used in the prothrombin time test. [Pg.1578]

The concept that different structural domains on the heparin chains are principally involved for optimal activity in the foregoing interactions could not be perceived in early work on structure-activity correlations, because the activity of heparin has been most frequently evaluated only with whole-blood-clotting tests (such as the U.S.P. assay). Development of assays for specific clotting-factors (especially Factor Xa and thrombin) has permitted a better insight into the mechanism of action of heparin at different levels of the coagulation cascade. [Pg.128]

When we tune the feedforward controller, we may take, as a first approximation, xFLD as the sum of the time constants xm and x v. Analogous to the "real" derivative control function, we can choose the lag time constant to be a tenth smaller, xFLG = 0.1 xFLD. If the dynamics of the measurement device is extremely fast, Gm = KmL, and if we have cascade control, the time constant x v is also small, and we may not need the lead-lag element in the feedforward controller. Just the use of the steady state compensator Kpp may suffice. In any event, the feedforward controller must be tuned with computer simulations, and subsequently, field tests. [Pg.196]

PU foam crumb must also have been made from PU foam block which meet the relevant requirements. Polystyrene foam beads are considered to have passed the test if the beads cascading from the specimen consistently extinguish the gas flame (Table Vil). [Pg.511]


See other pages where Tests cascade is mentioned: [Pg.284]    [Pg.42]    [Pg.43]    [Pg.184]    [Pg.344]    [Pg.284]    [Pg.42]    [Pg.43]    [Pg.184]    [Pg.344]    [Pg.198]    [Pg.279]    [Pg.309]    [Pg.29]    [Pg.208]    [Pg.573]    [Pg.983]    [Pg.178]    [Pg.434]    [Pg.294]    [Pg.697]    [Pg.363]    [Pg.151]    [Pg.922]    [Pg.1293]    [Pg.130]    [Pg.119]    [Pg.870]    [Pg.430]    [Pg.90]    [Pg.869]    [Pg.166]    [Pg.421]    [Pg.93]    [Pg.660]    [Pg.64]    [Pg.120]    [Pg.409]   


SEARCH



Compressors cascade test

Tiered Cascade of Testing

© 2024 chempedia.info