Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Biotinylated glucose oxidase

Fig. 26.2. Amperometric immunosensors set-up using a biotinylated copolymer poly(pyrrole-biotin, pyrrole-lactitob-ionamide) coated platinum or glassy carbon electrodes and three enzymatic markers (GOX-B, PPO-B, HRP-Ab) for the detection of cholera antitoxin. (A) HRP-immunosensor, (B) GOX-B-immunosensor, (C) PPO-B-immunosensor. Mred/Mox = hydroquinone/quinone Gox = biotinylated glucose oxidase PPO — biotinylated polyphenol oxidase HRP-Ab = peroxidase-labeled IgG anti-rabbit antibody. Fig. 26.2. Amperometric immunosensors set-up using a biotinylated copolymer poly(pyrrole-biotin, pyrrole-lactitob-ionamide) coated platinum or glassy carbon electrodes and three enzymatic markers (GOX-B, PPO-B, HRP-Ab) for the detection of cholera antitoxin. (A) HRP-immunosensor, (B) GOX-B-immunosensor, (C) PPO-B-immunosensor. Mred/Mox = hydroquinone/quinone Gox = biotinylated glucose oxidase PPO — biotinylated polyphenol oxidase HRP-Ab = peroxidase-labeled IgG anti-rabbit antibody.
Glucose oxidase polypyrrole biotinylated polypyrrole / avidin/biotinylated glucose oxidase amperometric 49... [Pg.12]

Enzyme labels are usually coupled to secondary antibodies or to (strept)avidin. The latter is used for detection of biotinylated primary or secondary antibodies in ABC methods (see Sect. 6.2.1). Enzyme labels routinely used in immunohisto-chemistry are horseradish peroxidase (HRP) and calf intestinal alkaline phosphatase (AP). Glucose oxidase from Aspergillus niger and E. coli (3-galactosidase are only rarely applied. [Pg.15]

M. Snejdarkova, M. Rehak and M. Otto, Design of a glucose minisensor based on streptavidin glucose-oxidase complex coupling with self-assembled biotinylated phospholipid membrane on solid support, Anal. Chem., 65 (1993) 665-668. [Pg.490]

Several examples of electrosynthesized PPy functionalized by redox-active groups like quinone derivatives, metallocene " or various metal complexes can be found in the literature. Other important functional PPy for bioanalytical applications can be cited, like biotinylated PPy for amperometric biosensors, oligonucleotide derivatized PPy for DNA biochips or PPy-glucose oxidase for glucose sensors. ... [Pg.249]

This immunosensor-type assay uses ferrocene methanol as co-substrate (redox mediator) of glucose oxidase (GOD). The various steps of the assay, shown in Fig. 8.20, are as follows (1) Covalent immobilization of protein A on graphite-polystyrene screen-printed electrodes (SPEs) (2) Addition of the rabbit IgG to be quantified which is captured specifically by protein A (3) Addition of a biotinylated goat anti-rabbit antibody (4) Addition of avidin-GOD conjugate (5) Addition of glucose and ferrocene methanol (6) Measurement of catalytic current by flow injection immunoassay. The voltammetric current corresponds to the one-electron oxidation of the ferrocenyl group to ferricinium. The electrode can subsequently be regenerated up to 30 times. The feasibility of the assay has been demonstrated for the case of monoclonal mouse anti-human prolactin (PL) with a detection limit of 0.02 pg mL [90]. [Pg.295]


See other pages where Biotinylated glucose oxidase is mentioned: [Pg.396]    [Pg.1139]    [Pg.54]    [Pg.494]    [Pg.1509]    [Pg.472]    [Pg.396]    [Pg.1139]    [Pg.54]    [Pg.494]    [Pg.1509]    [Pg.472]    [Pg.29]    [Pg.1143]    [Pg.133]    [Pg.29]    [Pg.30]    [Pg.55]    [Pg.561]    [Pg.152]    [Pg.160]    [Pg.454]    [Pg.5996]    [Pg.978]    [Pg.435]    [Pg.162]    [Pg.407]    [Pg.749]   
See also in sourсe #XX -- [ Pg.46 ]




SEARCH



Biotinylated

Glucose oxidase

© 2024 chempedia.info