Basic Principles of TOF-MS

Initially, the repeller and extractor electrodes are kept at the same electrical potential in order to prevent deflection of the incoming ions. To obtain a mass spectrum, this voltage [Pg.90]

Field-free flight region (tube) (length f) [Pg.91]

Consequently, measurement of the time-of-flight allows determination of mfz. The arrival times of the ions provide a spectrum in the time domain, which through application of Equation 3.41 is readily converted into the more usual mass spectrum. [Pg.91]

From the kinetic theory of gases we know that tiie mean free path of a gas particle is given by ksTIQ pa), where ks is the Boltzmann constant, T is the absolute terrqierature, p is tiie pressure (in Pa) and cr is die collision cross section (in m ). A reasonable estimate of the collision cross section between a small molecular ion and N2 or O2 is 50 = 5 x 10 m, and thus [Pg.91]