Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Attachment parameters

Table lb. The equilibrium factor (F), the free fraction (fp), the attachment parameters (X,0,d), the plateout rates (qf, qa) and the recoil factor (r ), calculated from the measured data of Table la (lo i/ ventilation). [Pg.298]

To determine the area of attachment, see Attachment Parameters. Please note that if a top (compression) plate is not used, then an equivalent rectangle that is equal to the moment of inertia of the attachment and whose width-to-height ratio is the same must be determined. The neural axis is the rotating axis of the lug passing through the centroid. [Pg.157]

Procedure 5-1 Stresses in Circular Rings, 256 Procedure 5-2 Design of Partial Ring Stiffeners, 265 Procedure 5-3 Attachment Parameters, 267... [Pg.514]

Figure 20 Electron current signal with attachment, parameter Xs/t (a) thick-layer method (b) thin-layer method. Figure 20 Electron current signal with attachment, parameter Xs/t (a) thick-layer method (b) thin-layer method.
The attachment parameter for both solid and hollow is for a cylinder ... [Pg.210]

The curves in WRC 107 are related to certain parameters at the intersection. The two important parameters are the shell parameter and the attachment parameter. The different applications on spherical and cylindrical shells follow. [Pg.566]

In the attachment parameter for all solid attachments, no parameter is needed. For a hollow cylinder (nozzle),... [Pg.566]

The OPLS force field is described in twtt papers, one discussing parameters for proteins W. L. Jorgensen and J. Tirado-Rives,/. Amer. (. hem. Soc., 110, 1557 (iy8K) and on e discii ssin g param eters for n iicleotide bases [J. Pranata, S. Wiersch ke, and W. L. Jorgen sen. , /.. Amer. Chem. Soc.. 117, 281(1 ( 1991)1. The force field uses the united atom concept ftir many, but not all. hydrttgens attached to carbons to allow faster calculation s on macromolecular systems. The amino and nucleic acid residue templates in HyperChein automatically switch to a united atom representation where appropriate when th e OPLS option is selected. [Pg.192]

In some force fields the interaction sites are not all situated on the atomic nuclei. For example, in the MM2, MM3 and MM4 programs, the van der Waals centres of hydrogen atoms bonded to carbon are placed not at the nuclei but are approximately 10% along the bond towards the attached atom. The rationale for this is that the electron distribution about small atoms such as oxygen, fluorine and particularly hydrogen is distinctly non-spherical. The single electron from the hydrogen is involved in the bond to the adjacent atom and there are no other electrons that can contribute to the van der Waals interactions. Some force fields also require lone pairs to be defined on particular atoms these have their own van der Waals and electrostatic parameters. [Pg.229]

Two Tq values are given for each MM+ bond, and rg . If rg is available (has a non-zero value in the parameter file) then it is used in preference to the normal for bonds where atom i and atom j have at least two hydrogen atoms directly attached to them. For example, CH2-CH2, CH2-CH3, or CH3-CH3 bonds may have their own equilibrium distance differentiated from the average single bond between carbon atoms. [Pg.184]

Eig. 3. Simulation parameters (a) splash onto cylindrical nosetip (b) attached wedge (—fixed -------, varied) and (c) detached wedge. See Table 3. [Pg.3]

H-nmr chemical shifts of N-1—H and N-3—H signals have been used as a criterion for distinguishing between N-l-substituted and N-3-substituted hydantoin derivatives (22). They can often be related to electronic properties, and thus good linear correlations have been found between the shifts of N—H and Hammett parameters of the substituents attached to the aryl group of 5-arylmethylenehydantoins (23). [Pg.250]

Mass Spectrometry. Field desorption mass spectrometry has been used to analy2e PPO (179). Average molecular weight parameters (M and could be determined using either protonated (MH + ) or cation attachment (MNa + ) ions. Good agreement was found between fdms and data supphed by the manufacturer, usually less than 5% difference in all cases up to about 3000 amu. Laser desorption Fourier transform mass spectrometry was used to measure PPG ion and it was claimed that ions up to m/2 9700 (PEG) can be analy2ed by this method (180). [Pg.354]


See other pages where Attachment parameters is mentioned: [Pg.80]    [Pg.244]    [Pg.299]    [Pg.267]    [Pg.268]    [Pg.268]    [Pg.435]    [Pg.448]    [Pg.448]    [Pg.449]    [Pg.244]    [Pg.80]    [Pg.244]    [Pg.299]    [Pg.267]    [Pg.268]    [Pg.268]    [Pg.435]    [Pg.448]    [Pg.448]    [Pg.449]    [Pg.244]    [Pg.66]    [Pg.37]    [Pg.399]    [Pg.403]    [Pg.625]    [Pg.2543]    [Pg.2826]    [Pg.2983]    [Pg.352]    [Pg.353]    [Pg.185]    [Pg.250]    [Pg.52]    [Pg.255]    [Pg.185]    [Pg.250]    [Pg.100]    [Pg.91]    [Pg.3]    [Pg.92]    [Pg.136]   


SEARCH



© 2024 chempedia.info