Annular-jet atomizers

In the empirical correlation proposed by Kato et al.,[503] the mean droplet size is inversely proportional to the water pressure, with a power index of 0.5 for conical shaped annular-jet atomizers, and 0.7-1.0 for V-shaped flat-jet atomizers. This suggests a lower efficiency of the annular-jet atomizers in terms of spray fineness at high water pressures. The data of Kato et al.15031 were obtained for water pressures lower than 10 MPa. Seki et al.15021 observed the similar trend in the water atomization of nickel and various steels at higher water pressures (>10 MPa). Since k is dependent on both... [Pg.289]


See other pages where Annular-jet atomizers is mentioned: [Pg.81]    [Pg.356]    [Pg.23]   
See also in sourсe #XX -- [ Pg.81 , Pg.290 ]