Andersen sampler

Table III Number of particles collected by the Andersen Sampler and weight of settled dust in an experimental piggery at different conditions from HONEY and McQUITTY (17)... Table III Number of particles collected by the Andersen Sampler and weight of settled dust in an experimental piggery at different conditions from HONEY and McQUITTY (17)...
Using an Andersen sampler, total counts of airborne BCFP ranged from 3 to 7 (/103) close to pigs. In general, values increased 3-fold as the pigs grew from 3 weeks to 7 weeks old and halved when internal filters were installed. [Pg.360]

The Andersen sampler is a six-stage circular jet impactor. Each stage has 400 jets of a certain diameter. For stage 3, the jet diameter is 0.028 in. For stage 4, the jet diameter is 0.021 in. Assuming a flow rate of 1 ft3/min and... [Pg.266]

Sayer, W.J. MacKnight, N.M. Wilson, H.W. Hospital airborne bacteria as estimated by the andersen sampler versus the gravity settling plate. Am. J. Clin. Path. 1972, 58, 558-562. [Pg.2314]

The Sierra 210 Series of impactors (Andersen Samplers, Inc.) consist of 10-, 8-, and 6-stage devices. These use radial slots rather than circular jets as described in the previous examples. The device is designed to offer the advantage of a greater number of stages in the submicrometer range at a selected flowrate that effectively renders it of little relevance to pharmaceutical aerosols. [Pg.371]

Figure 8 Schematic of the Andersen Sampler. (With permission of Andersen Samplers, Inc.)... Figure 8 Schematic of the Andersen Sampler. (With permission of Andersen Samplers, Inc.)...
Figure 2 Cross-sectional views of the Andersen sampler Mark II impactor, the Multi-Stage Liquid impinger, and the Marple-MiUer impactor. (From Ref. 6.)... Figure 2 Cross-sectional views of the Andersen sampler Mark II impactor, the Multi-Stage Liquid impinger, and the Marple-MiUer impactor. (From Ref. 6.)...
The Andersen PM 10/2.5 dichotomous sampler accurately monitors ambient air for coarse and fine particulates (Figure 6.26 Andersen Samplers Inc., 4215 Wendell Drive, Atlanta, GA 30336). The dichotomous (dichot) sampler separates aerosol particles into two distinct size fractions, 2.5 and 10 pm ( coarse particles) and less than 2.5 pm ( fine particles). The virtual... [Pg.151]

Fig. 10 (A) Andersen eight-stage nonviable inertial sampler. (B) Four-stage liquid impinger. Fig. 10 (A) Andersen eight-stage nonviable inertial sampler. (B) Four-stage liquid impinger.
The intrinsic germicidal property of the Ti02 support was also tested for natural indoor bioaerosol. A piece of cotton cloth was coated with a colloidal suspension of the nanostructured Ti02. After drying, a circular piece of the cloth was cut and fitted inside the Andersen viable single-stage sampler in such a way... [Pg.402]

Andersen, M. K., Raulund-Rasmussen, K., Strobel, B. W., and Hansen, H. C. B. (2002). Adsorption of cadmium, copper, nickel, and zinc to a poly(tetrafluorethene) porous soil solution sampler. [Pg.243]

Beier, C., Hansen, K., Gundersen, P., and Andersen, B. R. (1992). Long-term field comparison of ceramic and poly(tetrafluoroethene) porous cup soil water samplers. Environ. Sci. Technol. 26, 2005-2011. [Pg.243]

Although inventive, these samplers were cumbersome, as a result extensive sampling was impractical. The renaissance of aerobiology was essentially the mid 20th century when samplers were developed that made repeat observations feasible. The two chief samplers developed at this time were the Hirst spore trap and the Andersen culture impactor [2, 3]. The half-century since their development has seen aerobiology greatly expand and support fields such as plant... [Pg.10]

The true workhorses of aeroallergen samplers however, are all impactors (table 1). The rotorod, the Burkard (Hirst-type) spore trap, the personal Burkard, the Air-O-Cell, and the Andersen (several types) are all impactor... [Pg.12]

Andersen AA New sampler for the collection, sizing and enumeration of viable airborne particles. JBacteriol 1958 76 471 84. [Pg.25]

Given Andersen 2000 sampler data from an oil-fired boiler, you have been requested to plot a cumulative distribution ciuve on log-probability paper and determine the mean particle diameter and geometric standard deviation of the fly ash. Pertinent data are provided below. [Pg.938]

Stationary Jet-to-Agar Impactors Andersen Microbial Sampler (AMS) ... [Pg.87]

Leopold S.S. (1988) Positive hole statistical adjustment for a two stage, 200-hole-per-stage Andersen air sampler. Am. Ind. Hyg. Assoc. J., 49, 88-89. [Pg.100]

For the sampling of aerosols as a function of their size, a low pressure Andersen impactor (LPAI) sampler (Tokyo Dylec Co.) was operated with 25 L per minute... [Pg.372]

McFarland, A.R., Wedding, J.B., Cermak, J.E. (1977). Wind turmel evaluation of a modified Andersen Impacter and all-weather sampler inlet. Atmosph. Environment 11 535-539. Poreh, M., Cermak, J.E. (1959). Flow characteristics of circular submerged jet impinging normally on smooth boundary. Proc. 6 Midwestern Conf Fluid Mechanics Austin 198-212. [Pg.158]


See other pages where Andersen sampler is mentioned: [Pg.227]    [Pg.232]    [Pg.233]    [Pg.174]    [Pg.13]    [Pg.2314]    [Pg.370]    [Pg.160]    [Pg.13]    [Pg.276]    [Pg.276]    [Pg.227]    [Pg.232]    [Pg.233]    [Pg.174]    [Pg.13]    [Pg.2314]    [Pg.370]    [Pg.160]    [Pg.13]    [Pg.276]    [Pg.276]    [Pg.321]    [Pg.403]    [Pg.404]    [Pg.407]    [Pg.39]    [Pg.221]    [Pg.13]    [Pg.21]    [Pg.2311]    [Pg.310]    [Pg.345]    [Pg.348]    [Pg.86]    [Pg.236]    [Pg.279]    [Pg.291]   