Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Storage heat exchanger analysis

This chapter shows that chemical process systems may fail and have serious consequences to the workers, public and the environment. Comparing with Chapter 6, chemical processes are similar to the processes in a nuclear power plant, hence, they may be analyzed similarly because both consist of tanks, pipes heat exchangers, and sources of heat. As an example of analysis, we analyze a storage tank rupture. [Pg.304]

Figure 10 (a) Rising-droplet apparatus and (b) Venturi tube for droplet mass transfer experiments. (1—feed storage, 2—metering pump, 3—double-flow valve, 4, 5—pumps, 6—heat exchanger, 7—collecting funnel, 8—stream to analysis, 9—valve). [Pg.332]

Example 4.6 Entropy production in a packed duct flow Fluid flow and the wall-to-fluid heat transfer in a packed duct are of interest in fixed bed chemical reactors, packed separation columns, heat exchangers, and some heat storage systems. In this analysis, we take into account the wall effect on the velocity profile in the calculation of entropy production in a packed duct with the top wall heated and the bottom wall cooled (Figure 4.7). We assume... [Pg.168]

Becker, J. R. Analysis of Storage Type Heat Exchanger, The Marquardt... [Pg.133]

A second kind of problem encountered in heat exchanger analysis is the determination of the heal transfer rale and the outlet temperatures of the hot and cold fluids for prescribed fluid mass flow rales and inlet temperatures when the type and size of Ihe heat exchanger are specified. The heat transfer surface area of the heat exchanger in this case is known, but Ihe outlet temperatures are not. Here the task is to determine the heat transfer performance of a specified heat exchanger or to determine if a heat exchanger available in storage will do the job. [Pg.648]

Liquid anhydrous ammonia is used extensively as a coolant in heat exchange systems because of its chemical stability, low corrosiveness, and high latent heat of vaporization. However, anhydrous ammonia is readily contaminated during handling and storage. The gas chromatographic analysis of trace contaminants (O2, N2, CO, CH4, CO2, and water) in liquid ammonia was described by Mindmp and Taylor. An F M Model 5750 equipped with a Carle Microcavity Thermistor detector was used with dual columns for analysis. Table 9.3 lists the experimental parameters for both columns, which were conditioned for a minimum of 12 h at a temperature of 180°C and a... [Pg.329]

This chapter presented methods for scaling heat transfer equipment using dimensional analysis. We scaled heated, uninsulated storage tanks heated, insulated batch mixers and heat exchangers in this chapter. [Pg.138]


See other pages where Storage heat exchanger analysis is mentioned: [Pg.126]    [Pg.410]    [Pg.72]    [Pg.277]    [Pg.73]    [Pg.90]    [Pg.6]    [Pg.2433]    [Pg.122]    [Pg.122]    [Pg.442]    [Pg.602]    [Pg.29]   
See also in sourсe #XX -- [ Pg.121 ]




SEARCH



Heat exchangers analysis

© 2024 chempedia.info