As explained in Sec. 3. 3. 1.11, the fractional holdup of the dispersed phase in agitated extraction columns will vary with changing phase flow rate. This dynamic variation in the holdup along the column will cause a dynamic velocity profile in both phases. [Pg.556]

Figure 5.195. Flows of a single stage agitated extraction column. Figure 5.195. Flows of a single stage agitated extraction column.
Aerated tank with oxygen electrode 534 Agitated extraction column 556 Ammonia 567 Antoine equation 137 Area... [Pg.691]

The fractional holdup of the dispersed phase in agitated extraction columns varies as a function of flowrate. Under some circumstances it may be important to model the corresponding hydrodynamic effect. The system is represented below as a column containing seven agitated compartments or stages. [Pg.459]

Timothy C. Frank, Ph.D. Research Scientist and Sr. Technical Leader, The Dow Chemical Company Member, American Institute of Chemical Engineers (Section Editor, Introduction and Overview, Thermodynamic Basis for Liquid-Liquid Extraction, Solvent Screening Methods, Liquid-Liquid Diversion Fundamentals, Process Fundamentals and Basic Calculation Methods, Dual-Solvent Fractional Extraction, Extractor Selection, Packed Columns, Agitated Extraction Columns, Mixer-Settler Equipment, Centrifugal Extractors, Process Control Considerations, Liquid-Liquid Phase Separation Equipment, Emerging Developments)... [Pg.1687]

William D. Prince, M.S. Process Engineering Associate, The Dow Chemical Company Member, American Institute of Chemical Engineers (Extractor Selection, Agitated Extraction Columns, Mixer-Settler Equipment)... [Pg.1687]

Fischer [125] compared the suitability of a -paddle stirrer with vertical (free and also partly covered on both sides) and pitched paddles with a rotating disc for use in an agitated extraction columns (type Ktihni) and found, that the disc was not suitable for dispersion, whereas the three paddle stirrer arrangements were comparable in performance. [Pg.255]


See other pages where Extraction columns, agitated is mentioned: [Pg.699]    [Pg.699]    [Pg.331]    [Pg.1688]    [Pg.1693]    [Pg.1765]    [Pg.1765]    [Pg.1771]    [Pg.7]    [Pg.79]    [Pg.79]    [Pg.85]    [Pg.1682]    [Pg.1687]    [Pg.1759]    [Pg.1759]    [Pg.1765]    [Pg.363]    [Pg.308]    [Pg.421]   