Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About
0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | a | b | c | d | e | f | g | h | i | j | k | l | m | n | o | p | q | r | s | t | u | v | w | x | y | z

   |<      <<      >>     > |    


Nyquist plots of -2 represent the corresponding Bode plots.

Nyquist plots of a 20-mer of ds-DNA . The spectra were fit to the equivalent circuit shown on the top left individual elements of die equivalent circuit are summarized below

Nyquist plots of a charged lithium ion cell, a lithiated graphite graphite cell, and a delithiated cathode cathode symmetrical cell. The inset is an equivalent circuit used for the interpretation of the impedance spectra. Reproduced with permission from ref 512

Nyquist plots of a process and two alternative models.

Nyquist plots of a typical DMFC cathode impedance spectrum

Nyquist plots of copper in 0.1 M sodium chloride solution with or without benzo-hydroxamic acid derivatives 0.5 M NaCl , 1 x 10 M benzo-hydroxamic acids BHA

Nyquist plots of fuel cell impedance at different times under galvanostatic operation during progressive CO poisoning of the anode ,

Nyquist plots of mild steel in a model solution with different inhibitors after 30 min

Nyquist plots of mild steel in the model solution with DMPG for different times DMPG

Nyquist Plots of the Electrochemical Impedance on the SCA and the General Zone of the Lead-Silver Alloy Anode in Zinc Electrolyte at 38 . Polarization Potential was 1.345 V

Nyquist plots of the electrodeposited SngjNigg on Cu substrate measured after 2nd, modified Randles-Ershler model used to simulate the impedance spectra. Solid lines in

Nyquist plots of the hydride electrode simulated for different values of the diffusion coefficient .

Nyquist plots of the impedance spectra as measured for the fully charged lithium ion cells at —30 C in which the inset shows the magnified view of the high-frequency part. Electrolytes are 1.0 m LiPFe in PC EC EMC 1

Nyquist plots of the interpolated impedance spectra measured at 700 mV and different times during the progressive poisoning of the anode with CO ,

Nyquist plots of the normalized impedance results of 15 x 8 x 8 supercells obtained from kinetic Monte Carlo at 336 C. Reprinted from Reference , copyright 2007, with permission from Elsevier.

Nyquist plots of the screen-printed electrode

Nyquist plots of the sprayed electrode

Nyquist plots of uncoated and ZnO-coated LiNio.5Mn1.5O4 of fresh electrode and after 15 cycles at C 10 rate. EIS measurements were carried out in the charged state at55 C

Nyquist plots recorded in 0.01 M Cu solution at pH 4.9.Before measurements, the copper electrodes were exposed for the times indicated in the

Nyquist plots vs. Z J for Faradaic impedance measurements in the presence of 0.1 mol l phosphate buffer solution containing I.Ommol IKj FeJ 1

Nyquist representation and computer simulation

Nyquist representation of an R C circuit associated with a Warburg-type diffusion process

Nyquist representation of impedance data in 15 HCl for a one-layer .

Nyquist representation of impedance diagrams measured A for the fuel cell stack in parallel with the load, andU for the load, using the connections of

Nyquist representation of the impedance spectrum obtained with sintered beta-alumina associated with two gold electrodes, at various temperatures, and under air



   |<      <<      >>     > |    

SEARCH