Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

WSCC Furnace Model Calculations

Example 13 WSCC Furnace Model Calculations Consider the furnace geometry and combustion stoichiometry described in Example 12. The end-fired furnace is 3 m wide, 5 m tall, and 10 m long. Methane at a firing rate of 2500 kg/h is burned to completion with 20 percent excess air which is preheated to 600°C. The speckled furnace model is to be used. The sink (zone 1) [Pg.41]

Over this temperature range the gas emissivity may be calculated by linear interpolation. Additional heat-transfer and thermodynamic data are supplied in context. [Pg.41]

Zone 1 Sink (60 percent of total furnace area) [Pg.41]

Linear interpolation function for mean effective gas emissivity constants Yl(2000 K - T) + Y2- (T - 1500 K) [Pg.41]


See other pages where WSCC Furnace Model Calculations is mentioned: [Pg.688]    [Pg.698]    [Pg.688]    [Pg.698]    [Pg.41]    [Pg.727]    [Pg.737]   