Figure 12.5 Equivalent stator currents during unbalanced voltage... Figure 12.5 Equivalent stator currents during unbalanced voltage...
The unbalanced voltage will produce an additional rotor current at nearly twice the supply frequency. For example, for a 2% slip, i.e. a slip of 1 Hz, the negative sequence stator current, due to an unbalanced supply voltage, will induce a rotor current at a frequency of (2/- 1) = 99 Hz for a 50 Hz system. These high-frequency currents will produce significant skin effects in the rotor bars and cause high eddy current and hysteresis losses (Section 1.6.2(A-iv)). Total rotor heat may be represented by... [Pg.279]