Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Tungsten calibration curve

Fig. 7—8. Calibration curve for the determination of tungsten in solution with bromide as an internal standard, for two different counter tubes. Squares = krypton counted total count, 10(16,384) circles = argon counter total count, 5(16,384). (Fagel, Liebhafsky, and Zemany, Anal. Chem., 30, 1918.)... Fig. 7—8. Calibration curve for the determination of tungsten in solution with bromide as an internal standard, for two different counter tubes. Squares = krypton counted total count, 10(16,384) circles = argon counter total count, 5(16,384). (Fagel, Liebhafsky, and Zemany, Anal. Chem., 30, 1918.)...
Figure 7.13 Calibration curves for boron, tungsten and molybdenum from 0.0 to 4.0gg/ml (ppm) using scandium Sc as an internal standard. The units on the Y axis are flask numbers of standards 0.0, 1.0, 2.0, 3.0 4.0 ppm metal respectively... Figure 7.13 Calibration curves for boron, tungsten and molybdenum from 0.0 to 4.0gg/ml (ppm) using scandium Sc as an internal standard. The units on the Y axis are flask numbers of standards 0.0, 1.0, 2.0, 3.0 4.0 ppm metal respectively...
Fig. 15-9 Calibration curve for the determination of lead in oil. Ipt, is the intensity of the Pb La line. Tungsten-target tube (40 kV, 20 mA), LiF analyzing crystal, scintillation counter. Jenkins and DeVries [G.37]. Fig. 15-9 Calibration curve for the determination of lead in oil. Ipt, is the intensity of the Pb La line. Tungsten-target tube (40 kV, 20 mA), LiF analyzing crystal, scintillation counter. Jenkins and DeVries [G.37].
A tungsten electrode may be used to indicate the hydrogen ion concentration in solution the E-pH curve for tungsten is linear over the pH range 4-9, but may be calibrated for use from pH 2-12. The E-pH curve for a molybdenum electrode, which behaves in a similar manner, is linear in the pH range 3-13. Both electrodes are poisoned reversibly by hydrogen and irreversibly by copper ions. They are reliable only when cleaned regularly. [Pg.238]


See other pages where Tungsten calibration curve is mentioned: [Pg.196]    [Pg.459]    [Pg.704]    [Pg.111]    [Pg.248]    [Pg.575]    [Pg.235]    [Pg.326]    [Pg.732]    [Pg.95]    [Pg.180]    [Pg.31]    [Pg.347]    [Pg.43]    [Pg.190]    [Pg.115]    [Pg.180]    [Pg.351]    [Pg.354]    [Pg.326]    [Pg.522]    [Pg.403]    [Pg.522]    [Pg.30]    [Pg.273]    [Pg.273]    [Pg.274]    [Pg.425]    [Pg.52]   
See also in sourсe #XX -- [ Pg.215 ]




SEARCH



Calibration curve

© 2024 chempedia.info