Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Time-correlated single photon comparison

T. Louis, G.H. Schatz, P. Klein-Bolting, A.R. Holzwarth, G. Ripamonti, S. Cova, Performance comparison of a single-photon avalanche diode with a microchannel-plate photomultiplier in time-correlated single-photon counting, Rev. Sci. Instram. 59, 1148-1152 (1988)... [Pg.372]

Figure 11. Time-correlated single-photon counting rate histograms. Top Panel Plots obtained from a single Rhodamine-6G molecule on silica (trace A) and a bare silica substrate (background) < 10 nm under an NSOM probe (trace B). Center Panel Decays obtained for a higher coverage surface with the tip at a distance of <10 nm (trace C) and 1.1 micrometers (trace D) above the surface. Bottom Panel Traces obtained at lateral positions of maximum fluorescence intensity ( + lOnm) over different single Rhodamine-6G molecules. The extracted lifetime values are 4.6 (trace E), 3.4 (trace F), 2.1 (trace G) and 1.3 ns (trace H). The rates are normalized to 10 per second at zero time for slope comparisons. Background traces were subtracted in the center and bottom panels. Farfield powers (Top) 33 nW, (Center) 1.8 nW, and (Bottom) 20 nW. The bin width was 30.8 ps. Adapted from Ref. 21. Figure 11. Time-correlated single-photon counting rate histograms. Top Panel Plots obtained from a single Rhodamine-6G molecule on silica (trace A) and a bare silica substrate (background) < 10 nm under an NSOM probe (trace B). Center Panel Decays obtained for a higher coverage surface with the tip at a distance of <10 nm (trace C) and 1.1 micrometers (trace D) above the surface. Bottom Panel Traces obtained at lateral positions of maximum fluorescence intensity ( + lOnm) over different single Rhodamine-6G molecules. The extracted lifetime values are 4.6 (trace E), 3.4 (trace F), 2.1 (trace G) and 1.3 ns (trace H). The rates are normalized to 10 per second at zero time for slope comparisons. Background traces were subtracted in the center and bottom panels. Farfield powers (Top) 33 nW, (Center) 1.8 nW, and (Bottom) 20 nW. The bin width was 30.8 ps. Adapted from Ref. 21.

See other pages where Time-correlated single photon comparison is mentioned: [Pg.234]    [Pg.703]    [Pg.34]    [Pg.403]    [Pg.317]    [Pg.1215]    [Pg.26]    [Pg.155]    [Pg.418]   
See also in sourсe #XX -- [ Pg.103 ]




SEARCH



Correlation times

Photon correlation

Photon correlators

Single comparison

Single photon-timing

Time-correlated single photon

© 2024 chempedia.info