Thermoelectric power or thermopower

The Seebeck coefficient is frequently called the thermoelectric power or thermopower, and labeled Q or S. Neither of these alternatives is a good choice. The units of the Seebeck coefficient are not those of power. The symbol Q is most often used to signify heat transfer in materials. The designation S can easily be confused with the entropy of the mobile charge carriers, which is important because the Seebeck coefficient is equivalent to the entropy per mobile charge carrier (see Supplementary Material S3). [Pg.18]

The thermoelectric power, or thermopower, of the thermocouple is of the order of 2 to 50 iV/°C, depending on the metals and the temperature. In general, the thermopower decreases with decreasing temperature. Typically, in a thermocouple, the first junction is at Th, and the second, or reference junction, is held at the ice point of water (Tc = 0°C) (Fig. 10.21), or its electrical equivalent ("cold junction compensation"). [Pg.624]