The next point (7) concerns thermocouples. Chromel-alumel thermocouples are shown in Fig. 3.5 to be perhaps the most useful for DTA of intermediate... [Pg.131]

High temperatures were developed by resistive heating in a graphite heater. The temperature was measured by thermocouples chromel-alumel, up to 1470° C platinum-platinum rhodium, up to 1870° C and tungsten-rhenium, for higher temperatures. [Pg.395]

The Type N thermocouple (Table 11.60) is similar to Type K but it has been designed to minimize some of the instabilities in the conventional Chromel-Alumel combination. Changes in the alloy content have improved the order/disorder h ansformations occurring at 500°C and a higher silicon content of the positive element improves the oxidation resistance at elevated temperatures. [Pg.1216]

Temperature measurements ranging from 760 to 1760°C are made usiag iron—constantan or chromel—alumel thermocouples and optical or surface pyrometers. Temperature measuriag devices are placed ia multiple locations and protected to allow replacement without iaciaerator shutdown (see... [Pg.55]

Turbine exhaust. Thermocouple is constructed of Chromel-Alumel with an exposed junction. Nine to 12 units are required at this stage. [Pg.668]

Figure 1. Schematic Diagram of the off-axis radiant heated reactor. A. cell body B. linear/rotary motion feedthrough C. transport rod D. projector bulb E. reflector F. insulated stainless steel enclosure G. air cooling port H. gas inlet I. gas outlet/pumping port J. chromel/alumel thermocouple K. high vacuum gate valve L, sample mount. Figure 1. Schematic Diagram of the off-axis radiant heated reactor. A. cell body B. linear/rotary motion feedthrough C. transport rod D. projector bulb E. reflector F. insulated stainless steel enclosure G. air cooling port H. gas inlet I. gas outlet/pumping port J. chromel/alumel thermocouple K. high vacuum gate valve L, sample mount.
Figure 1 shows a schematic (elevation) of the Plastofrost apparatus as modified for the present study. The two main components are the heater and the coking attachment. The heater consists of a nickel-plated copper slab in which four 300 watt cartridge heaters are enclosed. A chromel/alumel thermocouple insulated with ceramic tubing placed 5 mm beneath the top surface of the slab measures the temperature (see Fig. 1). The bead of the TC is at the centre of the slab. Figure 2 is a photograph of the assembled apparatus. Figure 1 shows a schematic (elevation) of the Plastofrost apparatus as modified for the present study. The two main components are the heater and the coking attachment. The heater consists of a nickel-plated copper slab in which four 300 watt cartridge heaters are enclosed. A chromel/alumel thermocouple insulated with ceramic tubing placed 5 mm beneath the top surface of the slab measures the temperature (see Fig. 1). The bead of the TC is at the centre of the slab. Figure 2 is a photograph of the assembled apparatus.
A chromel-alumel thermocouple is used to monitor the temperature of the ceramic boat and also acts as a sensor for the furnace temperature controller. A constant flow of clean, dry N2 gas is maintained through the quartz tube. The metal vapor is carried out of the furnace with N2 and condensed to form a polydisperse aerosol. The primary aerosol is diluted by mixing with a filtered dry air stream. The diluted aerosol is then routed to the chamber as required and the excess aerosol is vented out through a glass fiber filter. [Pg.97]

Measurement of Volatile Matter Release Rates. Volatile matter release rates from anthracite were determined by using the apparatus shown diagram-matically in Figure 1. The power input to the 1-kw., 20-volt Hoskins tube furnace and transformer was controlled by means of a Leeds Northrup durationadjusting type program controller which permitted linear heating rates up to 20°C. per min. to be selected with varying soak times and temperatures. A maximum temperature of 1000°C. was used since this was the maximum temperature at which the furnace could be operated continuously. The temperature of the furnace was measured by a chromel-alumel thermocouple inside a... [Pg.597]

The catalyst was placed in the reactor and held by two small plugs of quartz wool. Prior to the reactions, the catalysts were heated in a helium stream (60 ml/min) at 450°C for 30 min and then heated in an ammonia stream at the reaction temperature for 30 min. The reaction temperature was measured by a chromel-alumel thermocouple placed adjacent to the catalytic zone of the reactor. For each pulse, 5 p of the reactant (chlorobenzene or benzaldehyde) were injected by a microsyringe. [Pg.500]

The temperature of a gas oil product flowing through a pipe is monitored using a chromel/alumel thermocouple. The measurement junction is inserted into the pipe and the reference junction is placed in the plant control room where the temperature is 20°C. The emf at the thermocouple junction is found to be 6.2 mV by means of a potentiometer connected into the thermocouple circuit adjacent to the reference junction. Find the measured temperature of the gas oil. [Pg.469]

The nickel single crystal(MARZ grade 99.995%, supplied by MRC) was metallographically polished down to 1 pm diamond paste, then chemically polished as described by Graham and Cohen (15). Transmission x-ray diffraction measurements confirmed the (100) direction of. the face to 0,0.5°. The specimen, of area o>2 cm2, was spot-welded to a nickel rod fastened to the specimen manipulator. It could be heated by electron bombardment or radiativity and cooled to vloO K through the nickel rod and a LN -cooled copper braid. A control unit held the crystal temperature (via a chromel-alumel thermocouple spot-welded to the back of the crystal) constant to within 1 K. [Pg.84]


See other pages where Chromel-alumel thermocouple is mentioned: [Pg.205]    [Pg.617]    [Pg.461]    [Pg.89]    [Pg.1161]    [Pg.160]    [Pg.90]    [Pg.147]    [Pg.212]    [Pg.205]    [Pg.617]    [Pg.461]    [Pg.89]    [Pg.1161]    [Pg.160]    [Pg.90]    [Pg.147]    [Pg.212]    [Pg.66]    [Pg.215]    [Pg.27]    [Pg.28]    [Pg.29]    [Pg.29]    [Pg.30]    [Pg.32]    [Pg.38]    [Pg.407]    [Pg.328]    [Pg.235]    [Pg.236]    [Pg.546]    [Pg.547]    [Pg.298]    [Pg.52]    [Pg.70]    [Pg.2]    [Pg.314]    [Pg.316]    [Pg.92]    [Pg.355]    [Pg.44]    [Pg.160]    [Pg.505]    [Pg.63]   