Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Test Case

We shall find estimates hm in numerical cases consisting of experimental data (Section XI.A) and simulated data (Section XI.B). In all cases, high-conviction form (20) will be assumed because the solutions hm are relatively easy to form and because of the ease with which prior knowledge Qm may be varied. In Section XI.A low photon occupancy nm/zm will be assumed, whereas in Section XI.B both low and high occupancies will be allowed. Note that low occupancy is consistent with maximum entropy according to Section IX.B, that is, particlelike behavior for the photons, whereas high occupancy is consistent with wavelike behavior for the photons. How, then, does the wave or particle nature of photons affect the estimates  [Pg.252]

Under the prior-knowledge conditions mentioned earlier, the principle given by Eqs. (56) and (57) is augmented by Eq. (41) to become [Pg.252]

By the form of the first sum, the object is being estimated by a principle of maximum cross entropy. By the second sum, the noise is being estimated by a principle of least squares (notice the minus sign). The df have dropped out because of the sparsity constraint (11a). This is convenient, because it avoids the need for their detailed calculation. [Pg.252]

The solution hm, em to Eq. (58) is obtained merely by setting d/dnm (all em fixed) of Eq. (58) equal to zero and by setting d/8em (all nm fixed) equal to zero. These result, respectively, in solutions [Pg.252]

Note from the form of Eq. (59a) that hm can only be positive, regardless of parameters and Xn. Hence, a positivity constraint is a natural consequence of the overall approach. For other cases of prior knowledge, such as the case of emission spectra, boundedness would result. By comparison, all other restoration methods that enforce positivity or boundedness do it in an ad hoc manner. [Pg.253]

To quantify the effects of handling on slurries, a series of experiments were performed. Tests 16 included handling and filtration experiments performed using silica-M slurry, whereas Tests 7-13 included experiments with silica-H slurry. Tests 14-15 and 16-17 involved handling and filtration tests conducted using low wt% abrasive alumina and ceria slurries, respectively. LPC and PSD from Tests 1-11 will be presented and discussed, and key findings of Tests 12-17 will be summarized as follows. [Pg.607]

It is important to note that present AccuSizer measurements were obtained with a particle-size threshold of 0.56 pm (the lowest possible size threshold available for this analyzer) and any LPC growth behavior for particles smaller than 0.56 pm could not be seen in these data. MLC pump extensive handling showed a slight increase in mean particle size and PSD of silica-H slurry, as will be discussed later. The above behavior of LPC may be attributed to the cumulative effects of low-intensity continuous shear application to the bulk volume of slurry handled at very high pump speeds in MLC pump. In Fig. 18.21b, the LPC trend for the complete 330 h of Test 1 is very similar to the first 45 h. [Pg.607]

FIGURE 18.21 LPC data for silica-M slurry recirculation in MLC pump at 8000 rpm and 31.7turnovers/h (Test 1). [Pg.608]

Results of comparable turnovers shown in Figs. 18.23a and 5.3b show a very similar and small growth in LPC for the first 140 turnovers of the slurry, demonstrating that the shearing effect on the slurry pumped by a MLC pump is a function of the number of turnovers rather than the recirculation time. [Pg.608]

Test 3 Silica-M was recirculated in an MLC pump at 5000 rpm, lOpsi back pressure, 39.6 turnovers/h, 51pm, for 24 h (950 turnovers). In contrast to Figs. 18.21-18.23 for the MLC pump tests at 8000 rpm. Fig. 18.24 for test at 5000 rpm does not show any increase in LPC, suggesting that the rate of shear or pump speed may be a factor in the LPC increase (i.e., in the particle-size range 0.56-0.60) in the tests at 8000 rpm. [Pg.608]

To probe the capabilities of ab initio molecular dyuamics (AIMD) in describing enzymatic reactions, calculations have been carried out on two text-book examples, human carbonic anhydrase II and serine proteeise. As these are among the most theoretically and experimentally characterized enzymes, this work has provided a basis for subsequent applications in the field. [Pg.221]

HCAII is a zinc-enzyme (260 amino acids, - 29 kD) which catalyzes the reversible hydration of CO2 to bicarbonate HCOj. The active site is located at the bottom of - 15 A deep conical cavity that is open towards the solvent. With a turnover rate at room temperature of HCAII is one of the faistest enzymes known. X-ray structures show that the [Pg.221]

Dummy hydrogen atoms have been used to saturate the QM model where covalent bonds had to be broken to cut out the cluster model from the rest of the protein. [Pg.222]

Our calculations show that the smallest size quantum model (MOD-A) does not provide an adequate description for neither structural, nor electronic or dynamical properties. In contrast, a cluster model of the size of MOD-B is able to reproduce the structural properties of the real system quite accurately and provides also a qualitative description of the electronic and dynamic features  [Pg.222]

In contrast, model B is able to retain the appropriate structure of the active site. In particular the zinc-oxygen distance in the hydroxide and in the water form are now similar [Pg.223]


Elamrani et al. 1996] Elamrani, S., Berry, M.B., Phillips Jr., G.N., McCammon, J.A. Study of Global Motions in Proteins by Weighted Masses Molecular Dynamics Adenylate Kinase as a Test Case. Proteins 25 (1996) 79-88 [Elcock et al. 1997] Elcock, A.H., Potter, M.J., McCammon, J.A. Application of Poisson-Boltzmann Solvation Forces to Macromolecular Simulations. In Computer Simulation of Biomoleeular Systems, Vol. 3, A.J. Wilkinson et al. eds., ESCOM Science Publishers B.V., Leiden... [Pg.76]

For both reactions leading to the two different regioisomers the corresponding vector was calculated and provided as a test case to the trained network of 626... [Pg.547]

The Bom-Oppenheimer approximation is not peculiar to the Huckel molecular orbital method. It is used in virtually all molecular orbital calculations and most atomic energy calculations. It is an excellent approximation in the sense that the approximated energies are very close to the energies we get in test cases on simple systems where the approximation is not made. [Pg.173]

For large molecules, the choice between semiempirical calculations and empirical calculations should be based on a test case. [Pg.254]

The iaterpretation of forensic toxicology (18) results is often challenging. Courts frequently ask if an amount of dmg detected ia a specimen could cause a specific type of behavior, ie, would someone be under the influence of a dmg at a specific concentration, would a particular dmg concentration cause diminished capacity, or was the dmg the cause of death In a random employee dmg testing case, a worker screened positive for opiates by EMIT and gc/ms analysis of the urine specimen showed low levels of morphine. Although one possibiUty was that the iadividual was a heroia user, a review of foods eaten ia the prior 24 hours suggested a more innocent cause a poppy-seed bagel. [Pg.486]

Vapor Cloud Source Dispersion Models (Workbook of Test Cases)... [Pg.103]

A complete analysis of dense gas dispersion is much beyond the scope of this treatise. More detailed references are available (Britter and McQuaid, Workbook on the Dispersion of Dense Gases, Health and Safety Executive Report No. 17/1988, England, 1988 Lees, 1986, pp. 455 61 Hanna and Drivas, 1987 Workbook of Test Cases for Vapor Cloud Source Dispersion Models, AlChE, 1989 Guidelines for Chemical Process Quantitative Risk Analysis, 1989, pp. 96-103). [Pg.2344]

Pages 1 and 2 list all the calculation details and execute a calculation for the center point condition of the former statistical study. This is done at 70 atmospheres hydrogen, 25 atmospheres carbon monoxide, and 5 atmospheres of methanol (all partial pressures), and at 485 K temperature. This is a test case because we know that the rate is 4 mol/m s at these conditions, and this is satisfied here. [Pg.221]

Intensity enhancement takes place on rough silver surfaces. Under such conditions, Raman scattering can be measured from monolayers of molecular substances adsorbed on the silver (pyridine was the original test case), a technique known as surface-enhanced Raman spectroscopy. More recendy it has been found that sur-fiice enhancement also occurs when a thin layer of silver is sputtered onto a solid sample and the Raman scattering is observed through the silver. [Pg.434]

Table I.IS gives total bonding energies in kilocalories per mole for some simple molecules. The B3iyP results are comparable in accuracy to G1 and G2 results. Another comparison was done with a series of cyclic hydrocarbons as the test case. The calculations were done using an isodesmic reaction scheme. The results are given in Table 1.19. Density functional calculations have also been successfully extended to functionalized molecules. ... Table I.IS gives total bonding energies in kilocalories per mole for some simple molecules. The B3iyP results are comparable in accuracy to G1 and G2 results. Another comparison was done with a series of cyclic hydrocarbons as the test case. The calculations were done using an isodesmic reaction scheme. The results are given in Table 1.19. Density functional calculations have also been successfully extended to functionalized molecules. ...
Thus, if the ratio AT//3 is constant, then the behavior shown in Fig. 12 could be described by the net solution. For many polymers, the characteristic ratio is around 7-10, the ratio Mo/j is the molecular weight per backbone bond (ca. 30-50) and will not vary extensively, b = 1.54 A and the density is about 1 g/cm such that the parameter is nearly constant. Since K is not very sensitive to the polymer properties, Eq. 6.5 is considered to describe the observed fracture behavior shown in Fig. 12. However, the data are not expected to fall on the straight line due to differences in K and j6 for each polymer. As a specific test case, consider... [Pg.382]

ISCST3 - Industrial Source Complex - Short Term This model is used in more detailed studies of maximum air quality impacts (Phase 3 - Refined Modeling Analysis). The purpose is to compute short term concentration or deposition values, from multiple sources, on specified locations (i.e., receptors). To download the file, click the filename. This is the latest version of the regulatory model ISCST3 (00101) which was released by U.S. EPA on April 27, 2000. The file ISCST.ZIP is 1.60 MB (Executable, Source, Test Cases). You can also download the ISCST3 model evaluation references. [Pg.329]

AREALTL.ZIP 7,787 bytes 09/18/95 (Area Source Test Case (Lahey))... [Pg.329]

AERMODEXB.ZIP 19 KB 10/11/01 (AERMOD Test Case) AERMETREADB.TXT 2.40 KB 10/15/01 (AERMET readme - read first)... [Pg.330]

AERMETSRB.ZIP 305 KB 10/15/01 (AERMET Source Code) AERMETTCB.ZIP 3.25 MB 10/15/01 (AERMET Test Case)... [Pg.330]

Download a copy of SCREEN (SCREEN can be downloaded from the publisher s site www.bh.com/companions/0750674997.) Try a few test cases (follow the examples in this chapter) to become familiar with the software. [Pg.344]

Hanna, S. R. and D. Strimaitis, 1989, Workbook of Test Cases for Vapour Cloud Dispersion Modes, CCPS, New York. [Pg.480]

Guidelines for the Use of Vapor Cloud Dispersion Models, the associated Workbook of Test Cases for Vapor Cloud Source Dispersion Models and research now in progress are directed toward a more complete understanding of the geographic areas affected by a release to the atmosphere. [Pg.281]

Arkin, A., Slien, P., and Ross, J., 1997. A test case of correlation metric construction of a reaction pathway from measurements. Science 277 1275-1279. [Pg.638]

Gradient corrected methods usually perform much better than LSDA. For the G2-1 data set (see Section 5.5), omitting electron affinities, the mean absolute deviations shown in Table 6.1 are obtained. The improvement achieved by adding gradient terms is impressive, and hybrid methods (like B3PW91) perform almost as well as the elaborate G2 model for these test cases. For a somewhat larger set of reference data, called the G2-2 set, the data shown in Table 6.2 are obtained. [Pg.188]

The Pd-Rh alloy system provides a convenient test case for application of the methodology because of its particularly simple phase diagram, which consists of only the liquid and a fee solid solution phases. [Pg.28]

Error Comparison of Test Case from Reference 91 ... [Pg.173]

It Is something of a miracle that quantum mechanics explains the periodic table to the extent that It does we should not let this fact seduce us into believing that It Is a deductive explanation. Attempts to explain the details of the periodic table continue to challenge the Ingenuity of quantum physicists and quantum chemists, and the periodic table will continue to present a test case for the adequacy of new methods developed in quantum chemistry. [Pg.146]

Here (in contrast to the approach taken in Chapter 2) we do not assume that the energy of each valence bond structure is correlated with its solvation-free energy. Instead we use the actual ground-state potential surface to calculate the ground-state free energy. To see how this is actually done let s consider as a test case an SN2 type reaction which can be written as... [Pg.84]

Up to this point it was assumed that the number of determinations n was sufficient for a given statistical test. During the discussion of the r-test (case a), an issue was skirted that demands more attention Is Xmean different from... [Pg.65]

It is easy to prove that there are differences between two given means using the t-test (Case bi or c). [Pg.135]


See other pages where Test Case is mentioned: [Pg.2]    [Pg.371]    [Pg.519]    [Pg.578]    [Pg.1972]    [Pg.2340]    [Pg.227]    [Pg.328]    [Pg.331]    [Pg.331]    [Pg.331]    [Pg.332]    [Pg.163]    [Pg.340]    [Pg.25]    [Pg.9]    [Pg.855]    [Pg.248]    [Pg.188]    [Pg.33]    [Pg.39]    [Pg.161]   
See also in sourсe #XX -- [ Pg.131 ]

See also in sourсe #XX -- [ Pg.6 , Pg.9 , Pg.11 , Pg.12 , Pg.13 , Pg.14 ]

See also in sourсe #XX -- [ Pg.190 , Pg.239 , Pg.240 , Pg.241 , Pg.242 , Pg.245 ]

See also in sourсe #XX -- [ Pg.113 , Pg.148 ]

See also in sourсe #XX -- [ Pg.271 , Pg.277 , Pg.278 ]




SEARCH



Atoms as a Test Case

Base case design pilot plant testing

Burning Test for the Medium Case Containing Caps

Case Study 4 Small Volume Dissolution Testing

Case studies with separate learning and test sets

Case-Control Tests

Documenting Test Activities in the Safety Case

EMTP Simulation Test Cases

Mn(CO)3(dab)- A test case for the isolobal relation

Protease-inhibitor Synthesis - A Demanding Test Case for Polymer Reagents

Published Test Cases

Seawater test case

Sterility testing specific cases

Test case description

Testing as Evidence for the Safety Case

Testing implementation approach case study

The FEBEX benchmark test. Case definition and comparison of different modelling approaches

Water test case, river

Worst-case test condition

Worst-case tests

© 2024 chempedia.info