Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Spatial encoding gradient

Figure 9 Stacked profile map (A) ofthe fluid velocity across the gap of a 7° cone and plate system containing a semidilute wormlike micelle solution, and shear rate image (B) obtained by taking the derivation of the velooity aoross the gap. Dramatic shear banding effects are apparent. Note the use of an expanded field of view across the gap achieved by using different magnitudes of spatial encoding gradients. Courtesy of MM Britton and the author. Figure 9 Stacked profile map (A) ofthe fluid velocity across the gap of a 7° cone and plate system containing a semidilute wormlike micelle solution, and shear rate image (B) obtained by taking the derivation of the velooity aoross the gap. Dramatic shear banding effects are apparent. Note the use of an expanded field of view across the gap achieved by using different magnitudes of spatial encoding gradients. Courtesy of MM Britton and the author.
Figure Bl.14.9. Imaging pulse sequence including flow and/or diflfiision encoding. Gradient pulses before and after the inversion pulse are supplemented in any of the spatial dimensions of the standard spin-echo imaging sequence. Motion weighting is achieved by switching a strong gradient pulse pair G, (see solid black line). The steady-state distribution of flow (coherent motion) as well as diffusion (spatially... Figure Bl.14.9. Imaging pulse sequence including flow and/or diflfiision encoding. Gradient pulses before and after the inversion pulse are supplemented in any of the spatial dimensions of the standard spin-echo imaging sequence. Motion weighting is achieved by switching a strong gradient pulse pair G, (see solid black line). The steady-state distribution of flow (coherent motion) as well as diffusion (spatially...
In order to avoid flow artifacts it may be advisable to replace the spatial encoding pulses (right-hand box) by velocity compensated pulses such as shown in Figure 2.9.4(e) for phase encoding. The amplitude of the Hahn spin-echo is attenuated by hydrodynamic dispersion. Evaluation of the echo attenuation curve for fixed intervals but varying preparation gradients (left box) permits the allocation of a hydrodynamic dispersion coefficient to each voxel, so that maps of this parameter can be rendered. [Pg.219]

SPRITE is termed a pure phase encode technique because spatial encoding occurs through the application of variable amplitude magnetic field gradients (which yield spatially varying frequencies) applied for fixed periods of time. Variable frequency with a fixed evolution or encoding time yields a variable signal phase. [Pg.286]

Fig. 4.2.5 Unaliased (A) and aliased (B) velocity images for a 0.6% aqueous carboxy-methylcellulose solution obtained by MRI. The vertical axes represent the data obtained in the velocity encoded direction and the horizontal axis represents data obtained in the spatially encoded direction. Aliasing is achieved by setting the velocity encode gradients so large that the maximum phase evolution of a given fluid element for a pulsed gradient step exceeds Ji or 2jt... Fig. 4.2.5 Unaliased (A) and aliased (B) velocity images for a 0.6% aqueous carboxy-methylcellulose solution obtained by MRI. The vertical axes represent the data obtained in the velocity encoded direction and the horizontal axis represents data obtained in the spatially encoded direction. Aliasing is achieved by setting the velocity encode gradients so large that the maximum phase evolution of a given fluid element for a pulsed gradient step exceeds Ji or 2jt...
Fig. 7 A chemical shift imaging pulse sequence. The MR signal is spatially encoded prior to acquiring the spectral signal in the absence of any applied magnetic field gradients. The shaded gradient pulses applied along z either side of the n refocusing pulse are homospoil gradients. Fig. 7 A chemical shift imaging pulse sequence. The MR signal is spatially encoded prior to acquiring the spectral signal in the absence of any applied magnetic field gradients. The shaded gradient pulses applied along z either side of the n refocusing pulse are homospoil gradients.

See other pages where Spatial encoding gradient is mentioned: [Pg.560]    [Pg.952]    [Pg.375]    [Pg.130]    [Pg.21]    [Pg.173]    [Pg.177]    [Pg.560]    [Pg.952]    [Pg.375]    [Pg.130]    [Pg.21]    [Pg.173]    [Pg.177]    [Pg.1521]    [Pg.1527]    [Pg.1536]    [Pg.29]    [Pg.43]    [Pg.154]    [Pg.214]    [Pg.287]    [Pg.393]    [Pg.513]    [Pg.597]    [Pg.598]    [Pg.952]    [Pg.952]    [Pg.290]    [Pg.295]    [Pg.225]    [Pg.20]    [Pg.21]    [Pg.124]    [Pg.125]    [Pg.205]    [Pg.206]    [Pg.173]    [Pg.407]    [Pg.288]    [Pg.314]    [Pg.332]    [Pg.111]    [Pg.112]    [Pg.113]    [Pg.1090]    [Pg.570]    [Pg.745]    [Pg.745]    [Pg.746]    [Pg.752]   
See also in sourсe #XX -- [ Pg.130 ]




SEARCH



ENCODE

Encoded

Encoding

Spatial gradients

© 2024 chempedia.info