Signal interferogram

I CRS interferogram with a frequency of A = coj + 2c0j - cOq, where cOp is the detected frequency, coj is the narrowband frequency and coj the Raman (vibrational) frequency. Since cOq and coj are known, Wj may be extracted from the experimentally measured RDOs. Furthemiore, the dephasing rate constant, yj, is detemiined from the observed decay rate constant, y, of the I CRS interferogram. Typically for the I CRS signal coq A 0. That is, the RDOs represent strongly down-converted (even to zero... [Pg.1209]

Transmission infrared spectra of species adsorbed on the catalyst were taken with a Digilab FTS-10M Fourier-transform infrared spectrometer, using a resolution of 4 cm-l. To improve the signal-to-noise ratio, between 10 and 100 interferograms were co-added. Spectra of the catalyst taken following reduction in H2 were subtracted from spectra taken in the presence of NO to eliminate the spectrum of the support. Because of the very short optical path through the gas in the reactor and the low NO partial pressures used in these studies, the spectrum of gas-phase NO was extremely weak and did not interfere with the observation of the spectrum of adsorbed species. [Pg.109]

The final step in obtaining the spectrum by the FTIR method is turning back the data obtained as a result of the repetitive interference action of the moving mirror into an intensity wavelength line. It is here that Fourier Transform mathematics is utilized. It is the signal intensity that is stored in a digital representation of the Interferogram. This information is then Fourier transformed by the computer into the frequency spectrum. [Pg.352]

A Fourier transform infrared spectroscopy spectrometer consists of an infrared source, an interference modulator (usually a scanning Michelson interferometer), a sample chamber and an infrared detector. Interference signals measured at the detector are usually amplified and then digitized. A digital computer initially records and then processes the interferogram and also allows the spectral data that results to be manipulated. Permanent records of spectral data are created using a plotter or other peripheral device. [Pg.31]


See other pages where Signal interferogram is mentioned: [Pg.34]    [Pg.210]    [Pg.113]    [Pg.113]    [Pg.104]    [Pg.34]    [Pg.210]    [Pg.113]    [Pg.113]    [Pg.104]    [Pg.1168]    [Pg.1200]    [Pg.1209]    [Pg.378]    [Pg.195]    [Pg.200]    [Pg.201]    [Pg.5]    [Pg.745]    [Pg.10]    [Pg.467]    [Pg.505]    [Pg.509]    [Pg.186]    [Pg.503]    [Pg.1006]    [Pg.313]    [Pg.396]    [Pg.136]    [Pg.136]    [Pg.141]    [Pg.251]    [Pg.8]    [Pg.404]    [Pg.151]    [Pg.82]    [Pg.250]    [Pg.31]    [Pg.220]    [Pg.34]    [Pg.35]    [Pg.195]    [Pg.130]    [Pg.309]    [Pg.4]    [Pg.18]    [Pg.162]    [Pg.163]    [Pg.165]    [Pg.98]    [Pg.316]   
See also in sourсe #XX -- [ Pg.104 ]




SEARCH



Interferograms

© 2024 chempedia.info