Routine maintenance turbomolecular pumps

Balzers TPU 170 and the Welch 3134 are good-quality turbomolecular pumps. They have an ultimate vacuum limit of 10 Torr and pumping speeds of 300 L s from 10 to 10 Torr. Other pumps with speeds up to 10,000 L s are available, although these rates are reduced somewhat for light gases such as H2 and He, which have high molecular velocities. The turbomolecular pump is a very clean pump, requires no trap between itself and the system, and is not sensitive to contamination (although in some cases the forepump should be protected by a cold trap). It is not widely used in routine laboratory applications however, as it is quite expensive and demands careful maintenance. [Pg.590]

Efficient high-vacuum pumps generally do not operate well near atmospheric pressure. Thus the vacuum system must have a mechanical vacuum pump to evacuate the system to a pressure where the high-vacuum pumps are effective. Mechanical pumps require routine maintenance, such as ballasting and replacing the pump oil. The diffusion pump is the least expensive and most reliable high-vacuum pump. Turbomolecular pumps and cryopumps are also used on mass analyzers. The high-vacuum pumps also require... [Pg.171]

Under normal circumstances, there is no need for the operator to be concerned about routine maintenance of the mass analyzer. With modem turbomolecular pumping systems, it is highly unlikely there will be any pump- or sample-related contamination problems associated with the quadrupole, magnetic sector, or TOP mass analyzer. This certainly was not the case with some of the early instruments that used oil-based diffusion pumps, because many researchers found that the quadrupole and prefllters were contaminated by oil vapors from the pumps. Today, it is fairly common for turbomolecular-based mass analyzers to require no maintenance of the quadrupole rods over the lifetime of the instrument, other than an inspection carried out by a service engineer on an annual basis. However, in extreme cases, particularly with older instruments, removal and cleaning of the quadrupole assembly might be required to get acceptable peak resolution and abundance sensitivity performance. [Pg.160]


See also in sourсe #XX -- [ Pg.160 ]




SEARCH



Maintenance pumps

Maintenance, routine

Pumping turbomolecular

Routine

Turbomolecular pump

© 2024 chempedia.info