For surge vessels, allow 2 min liquid residence time for drawoff, use 15 min for reflux use 5 min provided this allows sufficient time for controllers to function. Total volume = 1.3 X holdup if the holdup volume is > 3 m . [Pg.329]

For vaporAiquid separators there is often a liquid residence (holdup) time required for process surge. Tables 1, 2, and 3 give various rules of thumb for approximate work. The vessel design method in this chapter under the Vapor/Liquid Calculation Method heading blends the required liquid surge with the required vapor space to obtain the total separator volume. Finally, a check is made to see if the provided liquid surge allow s time for any entrained water to settle. [Pg.131]

Operating pressure and temperature constrain practical size of vessel. Design codes for pressure vessels vary slightly with the country. In general, for operating pressures >10 MPa, vessel volume usually <1 m Pressure decreases as temperatures exceed 250°C. For temperatures above 350°C, consider carbon/molybdenum, and for temperatures >500°C, consider austenitic steels. Corrosion allowance 1.5 mm for corrosion rates 0.08 mm/a 3 mm for rates 0.09 to 0.3 nun/a 4.5 nun for 0.31 to 0.4 mm/a 6 mm for >0.4 mm/a. If pressure <400 kPa, use L/D of 2 to 3 1. For pressures >400 kPa, use L/D of 4 to 5 1. For surge, allow 2-min liquid residence time for draw-off, use 15 min for reflux, use 5 min, provided this allows sufficient time for controllers to function. Total volume = 1.3 X holdup if the holdup volume is >3 m ... [Pg.1426]


See other pages where Residence surge vessels is mentioned: [Pg.10]    [Pg.493]    [Pg.483]    [Pg.103]    [Pg.243]   
See also in sourсe #XX -- [ Pg.329 ]




SEARCH



Surge vessels

© 2024 chempedia.info