Occasionally a vessel shell will sustain damage or be overground in a local area such that the thickness in the damaged area is below the minimum wall thickness. This is known as a Local Thin Area or LTA . ASME VIII-1 has allowance for such a case as long as certain proportions and guidelines are followed. These guidelines are taken from ASME Section VIII, Division 1, Mandatory Appendix 32 and are presented here. [Pg.432]

Maximum design temperature is less than shown in Table 6-16 for a given material. [Pg.433]

These rules do not apply to corrosion resistant lining or weld overlay. [Pg.433]

A pair of LTA with finished axial length, Li and L2, providing all of the conditions for a single LTA are met and all of the following  [Pg.433]

When 6 45 , the minimum axial separation shall be the greater of the following  [Pg.433]