Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Pentane-hexane splitter

I well remember one pentane-hexane splitter in Toronto. The tower simply could not make a decent split, regardless of the feed or reflux rate selected. The tower-top pressure was swinging between 12 and 20 psig. The flooded condenser pressure control valve, shown in Fig. 3.1, was operating between 5 and 15 percent open, and hence it was responding in a nonlinear fashion (most control valves work properly only at 20 to 75 percent open). The problem may be explained as follows. [Pg.25]


See other pages where Pentane-hexane splitter is mentioned: [Pg.229]   
See also in sourсe #XX -- [ Pg.65 ]