Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Multistage compression

Table 11-14 compares four basic systems using refrigerant 12, and generally indicates that the total horsepower can be reduced by using a multistage compression arrangement... [Pg.363]

Figure 8.41. Multistage compression cycle with interstage cooling... Figure 8.41. Multistage compression cycle with interstage cooling...
Multiphase systems, solids, liquids and gases 181 Multiple stage pumps, vacuum producing 365 Multistage compression 353 ----number of stages 354... [Pg.885]

In multistage compression, economy Is Improved with Interstage flashing and recycling, so-called economizer operation. [Pg.16]

A centrifugal compressor is to be used in place of the reciprocating compressor in Exercise 6. Estimate the power requirements. If multistage compression is to be used, assume no pressure drop in the intercooler with intercooling to 40°C. [Pg.290]

Figure 24.26 Multistage compression and expansion with an economizer. Figure 24.26 Multistage compression and expansion with an economizer.
Complex refrigeration cycles can be built up in different ways. Figure 24.29 shows a cascade cycle with multistage compression and expansion of the high-temperature cycle. [Pg.530]

An ideal Brayton cycle is modified to incorporate multistage compression with intercooling, and multistage expansion with reheating. As a result of these modifications, does the efficiency increase ... [Pg.196]

For an overall compression ratio much in excess of four or so, multistage compression is more economic. Figure 8.24(d) shows two stages with intercooling to improve the capacity and efficiency of the process. [Pg.224]

Optimal compression efficiency is achieved on machines that offer multistage compression with high precompression and main compression force flexibility (typically 100 kN maximum). The roller diameters should be as large as possible to provide the lowest possible rates of compression and decompression. If compression... [Pg.3619]

Multistage compression arrangement with inter-cooling... [Pg.70]

In multistage compression, economy is improved with interstage flashing and recycling, i.e., economizer operation. [Pg.457]

Process II. The limiting multistage expansion with = p then the limiting multistage compression with P = p. [Pg.112]

MULTISTAGE COMPRESSION REFRIGERATION SYSTEM - Where the refrigerant is vaporized and condensed alternately and is compressed in the vapor phase. [Pg.104]

With multistage compression, where the inlet temperature at each stage is the same due to intercooling, the total shaft work is given by... [Pg.497]


See other pages where Multistage compression is mentioned: [Pg.258]    [Pg.482]    [Pg.576]    [Pg.529]    [Pg.529]    [Pg.530]    [Pg.547]    [Pg.334]    [Pg.123]    [Pg.325]    [Pg.344]    [Pg.524]    [Pg.524]    [Pg.32]    [Pg.3611]    [Pg.3612]    [Pg.1082]    [Pg.3]    [Pg.110]    [Pg.186]    [Pg.259]    [Pg.809]   
See also in sourсe #XX -- [ Pg.353 ]




SEARCH



Compression of gases multistage

Compression of gases ratio, multistage

Compression, adiabatic multistage

Multistage