Matrix, mass-energy

The MALDI-TOF technique was first developed for the analysis of large biomolecules (Karas and others 1987). This technique presents some interesting characteristics. Of these, the high speed of analysis and the sensitivity of the technique have been pointed out as important advantages compared with other methods. In MALDI the samples are cocrystallized with a matrix that is usually composed of organic compounds, such as 3,5-dimethoxy-4-hydroxycinnamic acid (sinapic acid), 2, 4, 6 -trihydroxyacetophenone, a-cyano-4-hydroxycinnamic acid (alpha-cyano or alpha-matrix), and 2,5-dihydroxybenzoic acid (DHB). After the cocrystallization, the laser is fired and the matrix absorbs energy and allows a soft ionization of the samples. Afterward the ions are analyzed by a TOF mass spectrometer. [Pg.63]

A schematic of the basic principles of a matrix-assisted laser desorption/ion source is shown in Figure 2.35. By the interaction of a focused laser beam with short pulses and a suitable matrix, the energy of the photons is transferred to the matrix molecules. In MALDI mostly pulsed UV (e.g., nitrogen, X = 337 nm, pulse duration 3-10 ns), but also IR lasers (e.g., Er YAG, X = 2.94 (xm or C02, X = 10.6(xm with a higher pulse duration of up to 600 ns) are used. The MALDI mass spectra obtained during soft ionization by UV and IR lasers are identical. The energy density... [Pg.69]

The answer to the first task is fairly straightforward. We must construct a corresponding tiidiagonal system for the energy balance and solve the two sets of equations simultaneously. The same procedures may be used to construct the matrix of energy equations as for the mass balance some of the coefficients in the resultant matrix may also be dependent on fp and t. ... [Pg.438]

Energy levels can be tuned to provide implantation profiles over the appropriate depth region (Relation 3.6a reveals interrelations among R, energy, ion, and matrix mass)... [Pg.266]

The matrix M contains atomic masses on its diagonal, and the Hessian matrix F contains the second derivatives of the potential energy evaluated at Xq. [Pg.72]

Size reduction (qv) or comminution is the first and very important step in the processing of most minerals (2,6,10,20—24). It also involves large expenditures for heavy equipment, energy, operation, and maintenance. Size reduction is necessary because the value minerals are intimately associated with gangue and need to be Hberated, and/or because most minerals processing/separation methods require the ore mass to be of certain size and/or shape. Size reduction is also required in the case of quarry products to produce material of controlled particle size (see Size measurement of particles). In some instances, hberation of valuables or impurities from the ore matrix is achieved without any apparent size reduction. Scmbbers and attritors used in the industrial minerals plants, eg, phosphate, mtile, glass sands, or clay, ate examples. [Pg.396]

Mass spectrum obtained from the NIST Hasteloy Ni-basad standard alloy, using electron-gas SNMSd (Laybold INA-3). The sputtering energy was 1250 V, increasing the sputtered atom flux at the expense of depth resolution. Matrix ion currents ware about 10 cps, yielding background limHed detection at about 2 ppm. [Pg.577]

Figure 4 Mass spectrum obtained from the Aiuminium Peehiney standard Ai 11630, using eiectron-gas SNMSd with a sputtering energy of 1250 V. The AI matrix ion currerrt was significantly greater than 10 cps. yielding a background courrt rate limit less than 1 ppm. Figure 4 Mass spectrum obtained from the Aiuminium Peehiney standard Ai 11630, using eiectron-gas SNMSd with a sputtering energy of 1250 V. The AI matrix ion currerrt was significantly greater than 10 cps. yielding a background courrt rate limit less than 1 ppm.
Tandem mass spectrometry (MS/MS) is a method for obtaining sequence and structural information by measurement of the mass-to-charge ratios of ionized molecules before and after dissociation reactions within a mass spectrometer which consists essentially of two mass spectrometers in tandem. In the first step, precursor ions are selected for further fragmentation by energy impact and interaction with a collision gas. The generated product ions can be analyzed by a second scan step. MS/MS measurements of peptides can be performed using electrospray or matrix-assisted laser desorption/ionization in combination with triple quadruple, ion trap, quadrupole-TOF (time-of-flight), TOF-TOF or ion cyclotron resonance MS. Tandem... [Pg.1191]


See other pages where Matrix, mass-energy is mentioned: [Pg.290]    [Pg.482]    [Pg.444]    [Pg.163]    [Pg.290]    [Pg.238]    [Pg.178]    [Pg.178]    [Pg.50]    [Pg.29]    [Pg.1608]    [Pg.915]    [Pg.1331]    [Pg.2353]    [Pg.64]    [Pg.228]    [Pg.265]    [Pg.293]    [Pg.136]    [Pg.284]    [Pg.6]    [Pg.21]    [Pg.545]    [Pg.191]    [Pg.158]    [Pg.483]    [Pg.67]    [Pg.298]    [Pg.141]    [Pg.300]    [Pg.302]    [Pg.433]    [Pg.41]    [Pg.9]    [Pg.17]    [Pg.1029]   