Limestone Tests with Bleed Stream Oxidation. A major advantage of the bleed stream oxidation is its simple flow configuration. In operation without forced oxidation, the scrubber bleed stream would be sent directly to the solids dewatering system. [Pg.291]

Adipic Acid-Enhanced Limestone Test on the Venturi/Spray Tower System with Bleed Stream Oxidation... [Pg.292]

Table 7 gives the results of a typical bleed stream oxidation test, Run 915-1C, which was conducted with adipic acid-enhanced limestone on the venturi/spray tower system. The effluent slurries from the venturi and the spray tower were discharged into a common effluent hold tank. The scrubber bleed stream was pumped from the effluent hold tank to an oxidation tank into which air was injected through a 3-inch diameter pipe. The final system bleed was withdrawn from the oxidation tank and sent to the solids dewatering system. [Pg.291]