Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Latex cation exchanger

Fig. 3-132. Separation of alkali metals on a latex cation exchanger. - Separator column Fast-Sep Cation I chromatographic conditions see Fig. 3-129. Fig. 3-132. Separation of alkali metals on a latex cation exchanger. - Separator column Fast-Sep Cation I chromatographic conditions see Fig. 3-129.
Fig. 3-140. Separation of monoethylamine, di-ethylamine, and triethylamine on a latex cation exchanger. - Separator column IonPac CS3 eluent 0.04 mol/L HC1 flow rate 1 mL/min detection suppressed conductivity injection volume 50 pL solute concentrations 20 ppm monoethylamine, 50 ppm diethylamine, and 100 ppm triethylamine. Fig. 3-140. Separation of monoethylamine, di-ethylamine, and triethylamine on a latex cation exchanger. - Separator column IonPac CS3 eluent 0.04 mol/L HC1 flow rate 1 mL/min detection suppressed conductivity injection volume 50 pL solute concentrations 20 ppm monoethylamine, 50 ppm diethylamine, and 100 ppm triethylamine.
Fig. 4-17. Separation of some early eluting amino adds on a latex cation exchanger such as AminoPac PC-1. — Eluent i 0.0002S mol/L HN03 flow rate 1 mL/min detection fluor-... Fig. 4-17. Separation of some early eluting amino adds on a latex cation exchanger such as AminoPac PC-1. — Eluent i 0.0002S mol/L HN03 flow rate 1 mL/min detection fluor-...
The eluents suitable for the separation of amino acids on latex cation exchangers do not comprise the classical citrate/borate buffers but mixtures of nitric acid and potassium oxalate. In comparison to buffers composed of sodium citrate and borate, these components may be obtained at much higher purity. The retention of the amino acids to be analyzed, however, is possibly affected by the sample pH due to the limited buffer capacity of the eluents that are based on nitric acid and potassium oxalate. Fig. 4-21 shows the separation of a calibration standard for collagen hydrolysates on an Amino Pac PA-1 latex cation exchanger at ambient temperature. The advantage is the short... [Pg.231]

Cation exchangers are usually made of organic polymers (styrene-divinylbenzene, ethylvinylbenzene-diviniylbenzene, polymethacrylate, and polyvinyl), however, a variety of other substrate materials are also available (e.g., latexed cation exchangers, sUica-based exchangers). [Pg.1201]

Latex cation exchangers were introduced by Dionex Corp. 10 years later than latex-agglomerated anion exchangers. These types of cation exchangers consist of a weakly sulfonated PS-DVB substrate with latex beads with a very small diameter agglomerated on its surface by both electrostatic and van der Waals interactions. [Pg.1244]

In contrast to surface-sulfonated phases, latex cation exchangers exhibit a significantly higher chromatographic efficiency. Examples of Dionex latex cation-exchange columns are given in Table 9. [Pg.1245]

Table 9 Selected columns of latexed cation exchangers. Table 9 Selected columns of latexed cation exchangers.
Fig. 4-24. Schematic representation of a latexed cation exchange particle. Fig. 4-24. Schematic representation of a latexed cation exchange particle.
Fig. 4-56. Separation of transition metals on the lonPac CS5A bifunctional latexed cation exchanger. - Eluant ... Fig. 4-56. Separation of transition metals on the lonPac CS5A bifunctional latexed cation exchanger. - Eluant ...
Alternatively, uranyl cations can also be separated on an lonPac CS3 latexed cation exchanger utilizing a buffer mixture of ammonium sulfate and sulfuric acid as an eluant. Detection is performed as it is for transition metals, via derivatization with PAR. [Pg.341]

Fig. 4-59. Separation of aluminum on a latexed cation exchanger. -Separator column lonPac CS3 eluant 0.2 mol/L (NH4)2S04 + 0.01 mol/L H2SO4 flow rate 1 mL/mln detection photometry at 313 nm after derivatization with Tiron injection volume 50 jL solute concentration ... Fig. 4-59. Separation of aluminum on a latexed cation exchanger. -Separator column lonPac CS3 eluant 0.2 mol/L (NH4)2S04 + 0.01 mol/L H2SO4 flow rate 1 mL/mln detection photometry at 313 nm after derivatization with Tiron injection volume 50 jL solute concentration ...
The corresponding AminoPac PA-1 latexed anion exchanger, introduced at the same time as the AminoPac PC-1, has been replaced meanwhile by a more modern product, the AminoPac PA-10 (see Section 3.11). The baseline-resolved separation of 17 amino acids contained in a hydrolysate standard requires about 40 minutes, which is significantly longer than with a latex cation exchanger. [Pg.385]

Fig. 7-22. Pulse sequence for integrated amperometry of ethanolamines and their separation on a latexed cation exchanger. — Separator lonPac CSIO eluant ... Fig. 7-22. Pulse sequence for integrated amperometry of ethanolamines and their separation on a latexed cation exchanger. — Separator lonPac CSIO eluant ...

See other pages where Latex cation exchanger is mentioned: [Pg.173]    [Pg.173]    [Pg.174]    [Pg.174]    [Pg.175]    [Pg.175]    [Pg.185]    [Pg.196]    [Pg.204]    [Pg.228]    [Pg.229]    [Pg.1244]    [Pg.282]    [Pg.283]    [Pg.283]    [Pg.298]    [Pg.298]    [Pg.299]    [Pg.299]    [Pg.300]    [Pg.320]    [Pg.323]    [Pg.338]    [Pg.338]    [Pg.343]    [Pg.385]    [Pg.748]    [Pg.815]   
See also in sourсe #XX -- [ Pg.173 ]

See also in sourсe #XX -- [ Pg.298 ]




SEARCH



Cation exchange

Cation exchanger latex-agglomerated

Cation exchangers

Cation latexed

Cationic exchangers

Cationic latexes

Cations cation exchange

Exchangeable cations

Latexed Cation Exchangers

Latexed Cation Exchangers

© 2024 chempedia.info