Instrument profile rectangular

Figure 2.5 Calculated instrument profiles for three different entrance slit widths Sen, A Sen = 0 (pure sinc profile) B profile A convoluted by a rectangular profile with Sen = Sopi C profile A convoluted by a rectangular profile with Sen = 5 Sopi wavelength unit FWHM of sinc profile (A)... Figure 2.5 Calculated instrument profiles for three different entrance slit widths Sen, A Sen = 0 (pure sinc profile) B profile A convoluted by a rectangular profile with Sen = Sopi C profile A convoluted by a rectangular profile with Sen = 5 Sopi wavelength unit FWHM of sinc profile (A)...
Figure 2.11 Virtual CS AAS spectrometer with rectangular instrument profile... Figure 2.11 Virtual CS AAS spectrometer with rectangular instrument profile...
Figure 2.13 Calculated relationship between wavelength-integrated absorbance and peak (maximum) absorbance in the line center for Voigt-shaped absorption lines and a rectangular instrument profile curve parameter AAinsu, assumed stray light level 3 %... Figure 2.13 Calculated relationship between wavelength-integrated absorbance and peak (maximum) absorbance in the line center for Voigt-shaped absorption lines and a rectangular instrument profile curve parameter AAinsu, assumed stray light level 3 %...
Figure 2.14 Normalized, shot-noise determined, minimnm detectable absorbance for Gauss- and Lorentz-shaped absorption lines as function of AAinst rectangular instrument profile assumed... Figure 2.14 Normalized, shot-noise determined, minimnm detectable absorbance for Gauss- and Lorentz-shaped absorption lines as function of AAinst rectangular instrument profile assumed...
For a grating spectrograph with a relatively wide entrance slit the instrumental profile would be a rectangular function... [Pg.254]

The 180° inversion and refocusing pulses are particularly critical. When applied as simple rectangular pulses, these fail to cover the complete range of 13C frequencies even at lower field instruments. Smoothened chirp pulses show much better inversion profiles (Figure 6 A) and have been implemented into the ADEQUATE pulse sequence.28 These pulses are not suitable as refocusing pulses... [Pg.9]


See other pages where Instrument profile rectangular is mentioned: [Pg.11]    [Pg.22]    [Pg.71]    [Pg.236]    [Pg.277]    [Pg.283]    [Pg.182]    [Pg.72]    [Pg.136]    [Pg.2324]    [Pg.609]    [Pg.609]    [Pg.274]    [Pg.2313]   
See also in sourсe #XX -- [ Pg.12 , Pg.19 , Pg.22 ]