Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Hygas gasifier

Linearly extrapolated oxidation-corrosion data for the 1150 hr first exposure in the HYGAS gasifier offgas are plotted in Fig. 7. In this location at 580°F (average) carbon steel, AISI 410, AISI 304, IN-800, and titanium exhibited very limited corrosion. Alloy IN-600 and Monel 400 had corrosion rates of 42 and 124 mpy, respectively. [Pg.406]

Figure 8. Linearly extrapolated corrosion rates of selected alloys in HYGAS gasifier, heat exchanger bed... Figure 8. Linearly extrapolated corrosion rates of selected alloys in HYGAS gasifier, heat exchanger bed...
Corrosion data have been generated for metals in the quench systems and refractories in the gasifier. However, specific oxidation-corrosion data in this paper will be limited to metals exposed in the high-temperature gas phase locations of the HYGAS and CONOCO COAL plants. Again, the results reported will emphasize trends indicated by the pilot plant exposures. [Pg.404]


See other pages where Hygas gasifier is mentioned: [Pg.406]    [Pg.406]    [Pg.159]    [Pg.235]    [Pg.17]    [Pg.54]    [Pg.160]    [Pg.411]    [Pg.643]   
See also in sourсe #XX -- [ Pg.66 ]