Grid nebulizers

The sample solutions are made into aerosols by a nebulizer system and transported into the plasma with a carrier gas. Pneumatic, ultrasonic, or grid nebulizers are used for nebulizing the sample. Water or organic solvents can be removed from the aerosol by a desolvation unit if the plasma source cannot take large quantities without interference. [Pg.164]

Figure 111 Hildebrand grid nebulizer (Unicam Analytical Systems Ltd.)... Figure 111 Hildebrand grid nebulizer (Unicam Analytical Systems Ltd.)...
The interface between the chromatograph and ICP-MS consisted of a 40 cm length of 0.25 mm i.d. Teflon tubing connecting the end of the HPLC column to a Hildebrand grid nebulizer. A Scott-type double pass spray chamber was cooled to -8° C in order to minimize the amount of solvent vapor reaching the plasma. [Pg.58]

The spray approach requires the smallest amount of both specimen and stain. While this can be done with a pharmaceutical nebulizer, it is accomplished most easily by using a modified airbrush, such as that described by Tyler and Brandton (103). This device uses a plastic microliter pipet tip to hold the stain specimen mixture and allows the areosol dispersion of as little as 5 il-10 pi of the mixture. The target in this case is a coated grid. Since the droplets of stain/specimen jure so small (5 pl-20 pm in diameter), they dry-down rapidy, so there is less time for any drying defects to occur. When using either the nebulizer or airbrush approach,... [Pg.97]

Fig. 9. Electron micrograph (courtesy of Dr. R. C. Williams) of ribonucleopro-tein particles from pea seedlings, prepared according to Raacke JS6S). The particles, suspended in distilled water, were sprayed from a Vaponeferin nebulizer onto collo-dium-covered grids and shadowed with uranium at an angle of 3 1 the polystyrene reference particles are 2G0 m/i in diameter. Magnification X65,C00. Fig. 9. Electron micrograph (courtesy of Dr. R. C. Williams) of ribonucleopro-tein particles from pea seedlings, prepared according to Raacke JS6S). The particles, suspended in distilled water, were sprayed from a Vaponeferin nebulizer onto collo-dium-covered grids and shadowed with uranium at an angle of 3 1 the polystyrene reference particles are 2G0 m/i in diameter. Magnification X65,C00.

See other pages where Grid nebulizers is mentioned: [Pg.227]    [Pg.167]    [Pg.167]    [Pg.227]    [Pg.244]    [Pg.71]    [Pg.227]    [Pg.167]    [Pg.167]    [Pg.227]    [Pg.244]    [Pg.71]    [Pg.146]    [Pg.377]    [Pg.89]    [Pg.3856]    [Pg.146]    [Pg.8]    [Pg.72]   
See also in sourсe #XX -- [ Pg.167 ]