Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Ferrocenes mass transfer studies

In the previous section, we demonstrated the micrometer droplet size dependence of the ET rate across a microdroplet/water interface. Beside ET reactions, interfacial mass transfer (MT) processes are also expected to depend on the droplet size. MT of ions across a polarized liquid/liquid interface have been studied by various electrochemical techniques [9-15,87], However, the techniques are disadvantageous to obtain an inside look at MT across a microspherical liquid/liquid interface, since the shape of the spherical interface varies by the change in an interfacial tension during electrochemical measurements. Direct measurements of single droplets possessing a nonpolarized liquid/liquid interface are necessary to elucidate the interfacial MT processes. On the basis of the laser trapping-electrochemistry technique, we discuss MT processes of ferrocene derivatives (FeCp-X) across a micro-oil-droplet/water interface in detail and demonstrate a droplet size dependence of the MT rate. [Pg.194]

As suggested above, by recording an approach curve or voltammogram with the tip close to a substrate, one can study the rates of electron transfer reactions at electrode surfaces (Chapter 6). Because mass transfer rates at the small tip electrodes are high, measurements of fast reactions without interference of mass transfer are possible. As a rule of thumb, one can measure k° values (cm/s) that are of the order of Did, where D is the diffusion coefficient (cm2/s). For example, k° for ferrocene oxidation at a Pt electrode in acetonitrile solution was measured at a 1 /xm radius tip at a d of about 0.1 /xm yielded a value of 3.7 cm/s (24). The use of small tips and small currents decreases any interference from uncompensated resistance effects. [Pg.10]

Studies on the electrochemical behavior of ferrocene encapsulated in the hemi-carcerands 61 and 62, indicated that encapsulation induces substantial changes in the oxidation behavior of the ferrocene subunit [98]. In particular, encapsulated ferrocene exhibits a positive shift of the oxidation potential of c. 120 mV, probably because of the poor solvation of ferrocenium inside the apolar guest cavity. Lower apparent standard rate constants were found for the heterogeneous electron transfer reactions, compared to those found in the uncomplexed ferrocene under identical experimental conditions. This effect may be due to two main contributions (i) the increased effective molecular mass of the electroactive species and (ii) the increased distance of maximum approach of the redox active center to the electrode surface. [Pg.2158]


See other pages where Ferrocenes mass transfer studies is mentioned: [Pg.145]    [Pg.218]    [Pg.675]    [Pg.205]    [Pg.24]    [Pg.557]    [Pg.247]    [Pg.483]    [Pg.60]    [Pg.361]   
See also in sourсe #XX -- [ Pg.194 , Pg.195 , Pg.196 , Pg.197 , Pg.198 , Pg.199 , Pg.200 ]




SEARCH



Mass transfer study

© 2024 chempedia.info