Also, I ll inspect the installed trays to assure myself that the downcomer itself is not too flexible at its bottom edge. This is a good application for downcomer bracing brackets. [Pg.60]

In small-diameter towers using single-pass trays, this is not an issue. But, once a tower is larger than 8 ft in diameter or multipass trays are used, downcomer bracing brackets are critical. [Pg.62]

Failure to secure the side downcomer bracing brackets is a common installation error. So one needs to specify the spacing correctly, and then check the installation in the column. [Pg.62]

Figure 9.1 Downcomer bracing bracket prevents downcomer flexing. Figure 9.1 Downcomer bracing bracket prevents downcomer flexing.