A cardioid duct is shown in Fig. 5.63. Fully developed laminar flow and heat transfer under the boundary condition have been analyzed by Tyagi [294]. The/Re and NuHj values derived from this analysis are 5.675 and 4.208, respectively. The Nusselt number for the thermal boundary condition was found to be 4.097 [1]. [Pg.418]