The shear stress that the material experiences for flow across a blister mixer can be estimated using Eqs. 8.12 and 8.13. For this calculation, the flow in the axial direction is ignored to simplify the mathematics, and thus only the angular flow is considered. Ignoring the axial flow causes the calculated shear rate to be lower than in the actual channel. [Pg.360]


Figure 8.23 Schematic of blister ring mixers a) a blister mixer positioned in a metering section, b) blister section positioned at the discharge end of the screw near the tip, and c) the cross-sectional view showing the region of annular flow between the screw and barrel wall (courtesy of ieff A. Myers of Robert Barr, Inc)... Figure 8.23 Schematic of blister ring mixers a) a blister mixer positioned in a metering section, b) blister section positioned at the discharge end of the screw near the tip, and c) the cross-sectional view showing the region of annular flow between the screw and barrel wall (courtesy of ieff A. Myers of Robert Barr, Inc)...
Mixing screws — S-shaped kneader, Eagle mixing. Turbine mixing, Cohen double-wave, or Maillefer screws with pin-, blister ring-, fluted-, barrier-screw. Dynamic Extentional Flow Mixer (DEEM), etc. [Pg.602]