Atomic mass spectrometry limitations

The complex of the following destmctive and nondestmctive analytical methods was used for studying the composition of sponges inductively coupled plasma mass-spectrometry (ICP-MS), X-ray fluorescence (XRF), electron probe microanalysis (EPMA), and atomic absorption spectrometry (AAS). Techniques of sample preparation were developed for each method and their metrological characteristics were defined. Relative standard deviations for all the elements did not exceed 0.25 within detection limit. The accuracy of techniques elaborated was checked with the method of additions and control methods of analysis. [Pg.223]

Electrothermal vaporization can be used for 5-100 )iL sample solution volumes or for small amounts of some solids. A graphite furnace similar to those used for graphite-furnace atomic absorption spectrometry can be used to vaporize the sample. Other devices including boats, ribbons, rods, and filaments, also can be used. The chosen device is heated in a series of steps to temperatures as high as 3000 K to produce a dry vapor and an aerosol, which are transported into the center of the plasma. A transient signal is produced due to matrix and element-dependent volatilization, so the detection system must be capable of time resolution better than 0.25 s. Concentration detection limits are typically 1-2 orders of magnitude better than those obtained via nebulization. Mass detection limits are typically in the range of tens of pg to ng, with a precision of 10% to 15%. [Pg.638]

Mass Spectrometry. Mass spectrometry holds great promise for low-level toxin detection. Previous studies employed electron impact (El), desorption chemical ionization (DCI), fast atom bombardment (FAB), and cesium ion liquid secondary ion mass spectrometry (LSIMS) to generate positive or negative ion mass spectra (15-17, 21-23). Firm detection limits have yet to be reported for the brevetoxins. Preliminary results from our laboratory demonstrated that levels as low as 500 ng PbTx-2 or PbTx-3 were detected by using ammonia DCI and scans of 500-1000 amu (unpublished data). We expect significant improvement by manipulation of the DCI conditions and selected monitoring of the molecular ion or the ammonia adduction. [Pg.177]

In modern times, most analyses are performed on an analytical instrument for, e.g., gas chromatography (GC), high-performance liquid chromatography (HPLC), ultra-violet/visible (UV) or infrared (IR) spectrophotometry, atomic absorption spectrometry, inductively coupled plasma mass spectrometry (ICP-MS), mass spectrometry. Each of these instruments has a limitation on the amount of an analyte that they can detect. This limitation can be expressed as the IDL, which may be defined as the smallest amount of an analyte that can be reliably detected or differentiated from the background on an instrument. [Pg.63]

Mass spectrometry is the only universal multielement method which allows the determination of all elements and their isotopes in both solids and liquids. Detection limits for virtually all elements are low. Mass spectrometry can be more easily applied than other spectroscopic techniques as an absolute method, because the analyte atoms produce the analytical signal themselves, and their amount is not deduced from emitted or absorbed radiation the spectra are simple compared to the line-rich spectra often found in optical emission spectrometry. The resolving power of conventional mass spectrometers is sufficient to separate all isotope signals, although expensive instruments and skill are required to eliminate interferences from molecules and polyatomic cluster ions. [Pg.648]

Metastable atom bombardment (MAB) is a novel ionization method for mass spectrometry invented by Michel Bertrand s group at the University of Montreal, Quebec, Canada, and described by Faubert et al.38 For the identification of bacteria by MS, MAB has a number of significant advantages relative to more familiar ionization techniques. Electron ionization (El) imparts so much excess energy that labile biomolecules break into very small fragments, from which the diagnostic information content is limited since all... [Pg.104]

The detection limits for elements analyzed by ICP-mass spectrometry (ICP-MS) are significantly lower in most cases than the detection limits for other atomic techniques. See Table 10.1. See Workplace Scene 10.3. [Pg.292]

The elimination of arenes is not limited to the radical cations of the carotenoids. Just as the neutral compounds themselves also tend to undergo (thermal) cyclization followed by arene loss, the protonated analogues, e.g. ion 82 generated by Cl or fast atom bombardment (FAB) mass spectrometry are prone to eliminate one or even two arene molecules as well (Scheme 26)270. [Pg.46]


See other pages where Atomic mass spectrometry limitations is mentioned: [Pg.47]    [Pg.330]    [Pg.281]    [Pg.2462]    [Pg.676]    [Pg.356]    [Pg.171]    [Pg.321]    [Pg.134]    [Pg.405]    [Pg.46]    [Pg.529]    [Pg.530]    [Pg.532]    [Pg.625]    [Pg.634]    [Pg.228]    [Pg.134]    [Pg.53]    [Pg.50]    [Pg.152]    [Pg.267]    [Pg.178]    [Pg.370]    [Pg.68]    [Pg.475]    [Pg.443]    [Pg.25]    [Pg.26]    [Pg.106]    [Pg.231]    [Pg.125]    [Pg.340]    [Pg.21]    [Pg.21]    [Pg.31]    [Pg.58]    [Pg.730]    [Pg.227]    [Pg.76]    [Pg.188]    [Pg.102]   