Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Air humidifier

In the cooling tower the temperature of the liquid falls and the temperature and humidity of the air rise, and its action is thus similar to that of an air humidifier. The limiting temperature to which the water can be cooled is the wet-bulb temperature corresponding to the condition of the air at inlet. The enthalpy of the air stream does not remain... [Pg.763]

The cold recovery device consists of an exhaust air humidifier with an integrated heat exchanger and the supply air heat exchanger, which are connected by a fluid circuit. The first can be described as an indirect evaporative cooler. The cold recovery device is able to transport 83% of the maximum possible enthalpy difference from the exhaust air to the supply air. [Pg.419]

To prevent excessive dryness of the working atmosphere, which favours the build up of static electricity, wet cloths should be hung about the building or air-humidifying equipment used. [Pg.218]

Figure 4 Laboratory and pilot scale photocatalytic reactors. Keys (1) PCE + air, (2) air, (3) mass flowmeter, (4) air humidifier, (5) thermostatic bath, (6) heat exchanger, (7) thermohygrometer, (8) flat plate photoreactor, (9) sampling device, (10) recycle pump, (11) gas scrubber, (12) multiannular photocatalytic reactor. Figure 4 Laboratory and pilot scale photocatalytic reactors. Keys (1) PCE + air, (2) air, (3) mass flowmeter, (4) air humidifier, (5) thermostatic bath, (6) heat exchanger, (7) thermohygrometer, (8) flat plate photoreactor, (9) sampling device, (10) recycle pump, (11) gas scrubber, (12) multiannular photocatalytic reactor.
Fig. 38. Calculated water profiles in a Nafion 117 membrane within an operating PEFC as a function of current density. Cell and both hydrogen and air humidifiers are held at 80 °C [87], (Reprinted by permission of the Electrochemical Society). Fig. 38. Calculated water profiles in a Nafion 117 membrane within an operating PEFC as a function of current density. Cell and both hydrogen and air humidifiers are held at 80 °C [87], (Reprinted by permission of the Electrochemical Society).
Air Loop Air compressor/ expander Air mass flow sensors Air throttle body Air humidifier Air compressor/ expander Air mass flow sensor Air humidifier... [Pg.121]

For the cooling or humidification tower discussed, the operating line lies below the equilibrium line and water is cooled and air humidified. In a dehumidification tower cool water is used to reduce the humidity and temperature of the air that enters. In this case the operating line is above the equilibrium line. Similar calculation methods are used (Tl). [Pg.610]

In the most simple case as shown in Fig. 4.20, an active air supply subsystem consists of an air intake filter to remove particles and possibly impurities poisoning the cathode catalysts, a compressor or blower and an air humidifier that can also include the function of an air cooler. [Pg.119]

Floyd D.E. (2001) A simplified air humidifier using a porous metal membrane. Proceedings of the First European PEFC Forum (EFCF), pp. 417-423. [Pg.118]

Fig. 3 Long-term performance of a 22-cm air-pulsed DMFC (single cell). Cell voltage 0.5 V cell temperature 80°C anode l.OM CHjOH, 3 mL mincathode air humidified at the dew point of 90°C 200mL min", 0.7atm. back pressure. Air break performed for 4s every 100s. (Reproduced from Eickes et al. 2006)... Fig. 3 Long-term performance of a 22-cm air-pulsed DMFC (single cell). Cell voltage 0.5 V cell temperature 80°C anode l.OM CHjOH, 3 mL mincathode air humidified at the dew point of 90°C 200mL min", 0.7atm. back pressure. Air break performed for 4s every 100s. (Reproduced from Eickes et al. 2006)...
Perry LP et al. (1998) Pulmonary mycotoxicosis a clinicopath-ologic study of three cases. Mod Pathol ll(5) 432-436 Pestalozzi C (1959) [Febrile group diseases in a carpentry shop caused by inhalation of moisture from air humidifiers contaminated with molds.]. Schweiz Med Wochenschr 89 710-713... [Pg.64]


See other pages where Air humidifier is mentioned: [Pg.419]    [Pg.714]    [Pg.71]    [Pg.1097]    [Pg.143]    [Pg.159]    [Pg.70]    [Pg.835]    [Pg.18]    [Pg.1683]    [Pg.273]    [Pg.288]    [Pg.93]    [Pg.884]    [Pg.74]    [Pg.765]   
See also in sourсe #XX -- [ Pg.242 ]




SEARCH



Humidifier

Humidify