Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Acclaim Surfactant Plus

Figure 6.36 Separation of xylene sulfonate on a polar-embedded stationary phase. Separator column Acclaim Surfactant Plus, 3 pm column dimensions 150 mm x 3 mm i.d. column... Figure 6.36 Separation of xylene sulfonate on a polar-embedded stationary phase. Separator column Acclaim Surfactant Plus, 3 pm column dimensions 150 mm x 3 mm i.d. column...
CAD). In contrast to Hypersil 5 MOS, the elution order of the ethoxylated ether sulfates seems to be reversed on Acclaim Surfactant Plus, that is, retention increases with decreasing degree of ethoxylation. [Pg.623]

Figure 6.45 Gradient elution of various aliphatic quaternary ammonium compounds on a polar-embedded stationary phase. Separator column Acclaim Surfactant Plus, 3 pm column dimensions 150mmx3mm Ld. column temperature 25 °C eluent 5 mmol/L formic acid/ MeCN (95 5 v/v) and (B) 5 mmol/L formic add/ MeCN (60 40 v/v) gradient linear, 100% A to 100% B in 12 min flow rate 0.5 mL/min ... Figure 6.45 Gradient elution of various aliphatic quaternary ammonium compounds on a polar-embedded stationary phase. Separator column Acclaim Surfactant Plus, 3 pm column dimensions 150mmx3mm Ld. column temperature 25 °C eluent 5 mmol/L formic acid/ MeCN (95 5 v/v) and (B) 5 mmol/L formic add/ MeCN (60 40 v/v) gradient linear, 100% A to 100% B in 12 min flow rate 0.5 mL/min ...
Figure 10.189 Separation of xyiene sulfonate using mixed-mode liquid chromatography. Separator column Acclaim Surfactant Plus, 3pm column dimensions 150mmx3mm i.d. column temperature 30°C eluent MeCN/... Figure 10.189 Separation of xyiene sulfonate using mixed-mode liquid chromatography. Separator column Acclaim Surfactant Plus, 3pm column dimensions 150mmx3mm i.d. column temperature 30°C eluent MeCN/...
Figure 10.196 Separation of common cationic surfactants using mixed-mode liquid chromatography and charged aerosol detection. Separator column Acclaim Surfactant Plus, 3 pm column dimensions 150mmx3mm i.d. column temperature 30 °C eluent (A) MeCN and (B) 0.1 mol/L NH4OAC, pH 5 gradient 35% to 85% A (v/v) in 8 min flow rate 0.6mtymin detection Corona CAD (gain 100pA fiiten... Figure 10.196 Separation of common cationic surfactants using mixed-mode liquid chromatography and charged aerosol detection. Separator column Acclaim Surfactant Plus, 3 pm column dimensions 150mmx3mm i.d. column temperature 30 °C eluent (A) MeCN and (B) 0.1 mol/L NH4OAC, pH 5 gradient 35% to 85% A (v/v) in 8 min flow rate 0.6mtymin detection Corona CAD (gain 100pA fiiten...

See other pages where Acclaim Surfactant Plus is mentioned: [Pg.619]    [Pg.622]    [Pg.628]    [Pg.632]    [Pg.1183]    [Pg.1188]    [Pg.1192]    [Pg.1291]    [Pg.619]    [Pg.622]    [Pg.628]    [Pg.632]    [Pg.1183]    [Pg.1188]    [Pg.1192]    [Pg.1291]   
See also in sourсe #XX -- [ Pg.2 , Pg.2 , Pg.2 , Pg.619 , Pg.622 , Pg.626 ]




SEARCH



© 2024 chempedia.info