Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

A DETERMINATION OF ARSENIC BY ICP-MS

1 Solutions with arsenic compounds are nebulised into an argon plasma, where all components are vaporised. The ions produced are entrained in the plasma gas and introduced into a mass spectrometer, sorted according to their mass-to-charge ratios, and quantified with a channel electron multiplier. Arsenic is determined at mass 75 amu. [Pg.39]

2 This determination may be carried out on digest 2.3 (microwave digestion with [Pg.39]

HNO3 - HjOj. - HF), digest 2.4 (digestion with HNO, - - HF) and digest 2.7 [Pg.39]

1 This procedure yields a standard curve that is linear up to at least 50 pg/L As. [Pg.39]

2 The detection limit is approximately 0.007 pg/L in the digest. The determination limit is approximately 0.021 pg/L (2 respectively 7 pg/kg in the dried plant material). [Pg.39]